Dual energy computed tomography in tophaceous gout

被引:267
作者
Choi, H. K. [1 ,2 ]
Al-Arfaj, A. M. [2 ]
Eftekhari, A. [3 ]
Munk, P. L. [3 ]
Shojania, K. [2 ]
Reid, G. [2 ]
Nicolaou, S. [3 ]
机构
[1] Univ British Columbia, Div Rheumatol, Dept Med, Arthrit Res Ctr Canada, Vancouver, BC V5Z 1L7, Canada
[2] Univ British Columbia, Div Rheumatol, Vancouver Gen Hosp, Vancouver, BC V5Z 1L7, Canada
[3] Univ British Columbia, Dept Radiol, Vancouver Gen Hosp, Dept Med, Vancouver, BC V5Z 1L7, Canada
关键词
TOPHI;
D O I
10.1136/ard.2008.099713
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the potential utility of a dual energy CT (DECT) scan in assessing urate deposits among patients with tophaceous gout, and obtain computerised quantification of tophus volume in peripheral joints. Methods: 20 consecutive patients with tophaceous gout and 10 control patients with other arthritic conditions were included. DECT scans were performed using a renal stone colour-coding protocol that specifically assessed the chemical composition of the material (ie, urate coloured in red, calcium coloured in blue). An automated volumetric assessment of DECT was used to measure the volume of urate deposits in all peripheral joint areas. Results: All 20 patients with gout showed red colour-coded urate deposits on their DECT scans, whereas none of 10 controls showed urate deposits. DECT scans revealed a total of 440 areas of urate deposition in 20 patients, whereas physical examination showed 111 areas of urate deposition (mean 22 vs 6 per patient, respectively, p<0.001). Total urate volume in a given patient ranged from 0.63 cm(3) to 249.13 cm(3), with a mean of 40.20 cm(3). Conclusions: DECT scans can produce obvious colour displays for urate deposits and help to identify subclinical tophus deposits. Furthermore, tophus volume can be measured by DECT scans through an automated volume estimation procedure.
引用
收藏
页码:1609 / 1612
页数:4
相关论文
共 15 条
[11]   Imaging modalities and monitoring measures of gout [J].
Perez-Ruiz, Fernando ;
Naredo, Esperanza .
CURRENT OPINION IN RHEUMATOLOGY, 2007, 19 (02) :128-133
[12]   Dual-source computed tomography - Advances of improved temporal resolution in coronary plaque imaging [J].
Reimann, Anja J. ;
Rinck, Daniel ;
Birinci-Aydogan, Ayser ;
Scheuering, Michael ;
Burgstahler, Christof ;
Schroeder, Stephen ;
Brodoefel, Harald ;
Tsiflikas, Ilias ;
Herberts, Tina ;
Flohr, Thomas ;
Claussen, Claus D. ;
Kopp, Andreas F. ;
Heuschmid, Martin .
INVESTIGATIVE RADIOLOGY, 2007, 42 (03) :196-203
[13]   Magnetic resonance imaging in the quantitative assessment of gouty tophi [J].
Schumacher, HR ;
Becker, MA ;
Edwards, NL ;
Palmer, WE ;
MacDonald, PA ;
Palo, W ;
Joseph-Ridge, N .
INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2006, 60 (04) :408-414
[14]  
Schumacher HR, 2005, J RHEUMATOL, V32, P2452
[15]   Diagnosis of gout by ultrasound [J].
Thiele, R. G. ;
Schlesinger, N. .
RHEUMATOLOGY, 2007, 46 (07) :1116-1121