Dual-source computed tomography - Advances of improved temporal resolution in coronary plaque imaging

被引:60
作者
Reimann, Anja J.
Rinck, Daniel
Birinci-Aydogan, Ayser
Scheuering, Michael
Burgstahler, Christof
Schroeder, Stephen
Brodoefel, Harald
Tsiflikas, Ilias
Herberts, Tina
Flohr, Thomas
Claussen, Claus D.
Kopp, Andreas F.
Heuschmid, Martin
机构
[1] Eberhard Karls Univ Tubingen, Dept Diagnost Radiol, Tubingen, Germany
[2] Siemens Med Solut, Forchheim, Germany
[3] Eberhard Karls Univ Tuebingen, Dept Cardiol, Tubingen, Germany
[4] Eberhard Karls Univ Tuebingen, Dept Med Biometrie, Tubingen, Germany
关键词
cardiac imaging; dual source computed tomography; image quality; phantom study;
D O I
10.1097/01.rli.0000254409.79193.96
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to quantify image quality gains of a moving coronary plaque phantom using dual-source computed tomography (DSCT) providing 83 milliseconds temporal resolution in direct comparison to 64 slice single-source multidetector CT (MDCT) with a temporal resolution of 165 milliseconds. Materials and Methods: Three cardiac vessel phantoms with fixed 50% stenosis and changing plaque configurations were mounted on a moving device simulating cardiac motion. Scans were performed at a simulated heart frequency of 60 to 120 bpm. Image quality assessment was performed in different anatomic orientations inside a thoracic phantom. Results: A significant improvement of image quality using the DSCT could be found (P = 0.0002). Relevant factors influencing image quality aside from frequency (P = 0.0002) are plaque composition (P < 0.0001), as well as orientation (P < 0.0001). Conclusion: Scanning with 83 milliseconds temporal resolution improved image quality of coronary plaque at higher heart frequencies.
引用
收藏
页码:196 / 203
页数:8
相关论文
共 43 条
[1]   Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]   Current and future status on cardiac computed tomography imaging for diagnosis and risk stratification [J].
Achenbach, S .
JOURNAL OF NUCLEAR CARDIOLOGY, 2005, 12 (06) :703-713
[3]   Editorial comment - Detection of coronary stenoses by multidetector computed tomography: It's all about resolution [J].
Achenbach, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :840-841
[4]   Noninvasive coronary angiography - An acceptable alternative? [J].
Achenbach, S ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (26) :1909-1910
[5]  
Achenbach S, 2001, AM J CARDIOL, V88, p70E
[6]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[7]   Clinical use of multislice spiral computed tomography in 210 highly preselected patients: experience with 4 and 16 slice technology [J].
Beck, T ;
Burgstahler, C ;
Kuettner, A ;
Kopp, AF ;
Heuschmid, M ;
Claussen, CD ;
Schroeder, S .
HEART, 2005, 91 (11) :1423-1427
[8]   Noninvasive detection of coronary stenosis using 16-slice detector computed tomography in carefully selected patients [J].
Beck, T ;
Kuettner, A ;
Burgstahler, C ;
Brückner, A ;
Heuschmid, M ;
Herdeg, C ;
Kopp, AE ;
Claussen, CD ;
Schroeder, S .
MEDIZINISCHE KLINIK, 2004, 99 (11) :645-650
[9]   Non-invasive coronary angiography with 16-slice spiral computed tomography:: image quality in patients with high heart rates [J].
Brodoefel, H ;
Reimann, A ;
Heuschmid, M ;
Küttner, A ;
Beck, T ;
Burgstahler, C ;
Claussen, CD ;
Schroeder, S ;
Kopp, AF .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1434-1441
[10]   LUMEN DIAMETER OF NORMAL HUMAN CORONARY-ARTERIES - INFLUENCE OF AGE, SEX, ANATOMIC VARIATION, AND LEFT-VENTRICULAR HYPERTROPHY OR DILATION [J].
DODGE, JT ;
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
CIRCULATION, 1992, 86 (01) :232-246