Dual-source computed tomography - Advances of improved temporal resolution in coronary plaque imaging

被引:60
作者
Reimann, Anja J.
Rinck, Daniel
Birinci-Aydogan, Ayser
Scheuering, Michael
Burgstahler, Christof
Schroeder, Stephen
Brodoefel, Harald
Tsiflikas, Ilias
Herberts, Tina
Flohr, Thomas
Claussen, Claus D.
Kopp, Andreas F.
Heuschmid, Martin
机构
[1] Eberhard Karls Univ Tubingen, Dept Diagnost Radiol, Tubingen, Germany
[2] Siemens Med Solut, Forchheim, Germany
[3] Eberhard Karls Univ Tuebingen, Dept Cardiol, Tubingen, Germany
[4] Eberhard Karls Univ Tuebingen, Dept Med Biometrie, Tubingen, Germany
关键词
cardiac imaging; dual source computed tomography; image quality; phantom study;
D O I
10.1097/01.rli.0000254409.79193.96
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to quantify image quality gains of a moving coronary plaque phantom using dual-source computed tomography (DSCT) providing 83 milliseconds temporal resolution in direct comparison to 64 slice single-source multidetector CT (MDCT) with a temporal resolution of 165 milliseconds. Materials and Methods: Three cardiac vessel phantoms with fixed 50% stenosis and changing plaque configurations were mounted on a moving device simulating cardiac motion. Scans were performed at a simulated heart frequency of 60 to 120 bpm. Image quality assessment was performed in different anatomic orientations inside a thoracic phantom. Results: A significant improvement of image quality using the DSCT could be found (P = 0.0002). Relevant factors influencing image quality aside from frequency (P = 0.0002) are plaque composition (P < 0.0001), as well as orientation (P < 0.0001). Conclusion: Scanning with 83 milliseconds temporal resolution improved image quality of coronary plaque at higher heart frequencies.
引用
收藏
页码:196 / 203
页数:8
相关论文
共 43 条
[11]   New technical developments in multislice CT - Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning [J].
Flohr, T ;
Stierstorfer, K ;
Bruder, H ;
Simon, J ;
Schaller, S .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (07) :839-845
[12]   Performance evaluation of a 64-slice CT system with z-flying focal spot [J].
Flohr, T ;
Stierstorfer, K ;
Raupach, R ;
Ulzheimer, S ;
Bruder, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12) :1803-1810
[13]   Multi-detector row CT systems and image-reconstruction techniques [J].
Flohr, TG ;
Schaller, S ;
Stierstorfer, K ;
Bruder, H ;
Ohnesorge, BM ;
Schoepf, UJ .
RADIOLOGY, 2005, 235 (03) :756-773
[14]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[15]   Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot [J].
Flohr, TG ;
Stierstorfer, K ;
Ulzheimer, S ;
Bruder, H ;
Primak, AN ;
McCollough, CH .
MEDICAL PHYSICS, 2005, 32 (08) :2536-2547
[16]   Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection [J].
Giesler, T ;
Baum, U ;
Ropers, D ;
Ulzheimer, S ;
Wenkel, E ;
Mennicke, M ;
Bautz, W ;
Kalender, WA ;
Daniel, WG ;
Achenbach, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) :911-916
[17]   Multislice spiral computed tomographic angiography of coronary arteries in patients with suspected coronary artery disease:: An effective filter before catheter angiography? [J].
Haberl, R ;
Tittus, J ;
Böhme, E ;
Czernik, A ;
Richartz, BM ;
Buck, J ;
Steinbigler, P .
AMERICAN HEART JOURNAL, 2005, 149 (06) :1112-1119
[18]   ECG-gated 16-MDCT of the coronary arteries: Assessment of image quality and accuracy in detecting stenoses [J].
Heuschmid, M ;
Kuettner, A ;
Schroeder, S ;
Trabold, T ;
Feyer, A ;
Seemann, MD ;
Kuzo, R ;
Claus, CD ;
Kopp, AF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (05) :1413-1419
[19]   Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time:: first experiences [J].
Heuschmid, M ;
Küttner, A ;
Flohr, T ;
Wildberger, JE ;
Lell, M ;
Kopp, AF ;
Schröder, S ;
Baum, U ;
Schaller, S ;
Hartung, A ;
Ohnesorge, B ;
Claussen, CD .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (06) :721-724
[20]   Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate [J].
Hoffmann, MHK ;
Shi, HS ;
Manzke, R ;
Schmid, FT ;
De Vries, L ;
Grass, M ;
Brambs, HR ;
Aschoff, AJ .
RADIOLOGY, 2005, 234 (01) :86-97