Impact of velocity distribution assumption on simplified laser speckle imaging equation

被引:115
作者
Ramirez-San-Juan, Julio C. [1 ]
Ramos-Garcia, Ruben [1 ]
Guizar-Iturbide, Ileana [1 ]
Martinez-Niconoff, Gabriel [1 ]
Choi, Bernard [2 ,3 ]
机构
[1] Inst Nacl Astrofis Opt Elect, Dept Opt, Puebla 72840, Mexico
[2] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA
[3] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92612 USA
关键词
D O I
10.1364/OE.16.003197
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Since blood flow is tightly coupled to the health status of biological tissue, several instruments have been developed to monitor blood flow and perfusion dynamics. One such instrument is laser speckle imaging. The goal of this study was to evaluate the use of two velocity distribution assumptions (Lorentzian- and Gaussian-based) to calculate speckle flow index (SFI) values. When the normalized autocorrelation function for the Lorentzian and Gaussian velocity distributions satisfy the same definition of correlation time, then the same velocity range is predicted for low speckle contrast (0 < C < 0.6) and predict different flow velocity range for high contrast. Our derived equations form the basis for simplified calculations of SFI values. (c) 2007 Optical Society of America.
引用
收藏
页码:3197 / 3203
页数:7
相关论文
共 23 条
[1]   Intrinsic brain activity triggers trigeminal meningeal afferents in a migraine model [J].
Bolay, H ;
Reuter, U ;
Dunn, AK ;
Huang, ZH ;
Boas, DA ;
Moskowitz, MA .
NATURE MEDICINE, 2002, 8 (02) :136-142
[2]  
Bracewell R.N., 1965, The Fourier Transform and Its Applications
[3]   QUASI REAL-TIME DIGITAL VERSION OF SINGLE-EXPOSURE SPECKLE PHOTOGRAPHY FOR FULL-FIELD MONITORING OF VELOCITY OR FLOW-FIELDS [J].
BRIERS, JD ;
WEBSTER, S .
OPTICS COMMUNICATIONS, 1995, 116 (1-3) :36-42
[4]  
BRIERS JD, 1983, P SOC PHOTO-OPT INST, V369, P22, DOI 10.1117/12.934340
[5]   Capillary blood flow monitoring using laser speckle contrast analysis (LASCA) [J].
Briers, JD ;
Richards, G ;
He, XW .
JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) :164-175
[6]   Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media [J].
Chen, ZP ;
Milner, TE ;
Dave, D ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (01) :64-66
[7]   Simplified laser-speckle-imaging analysis method and its application to retinal blood flow imaging [J].
Cheng, Haiying ;
Duong, Timothy Q. .
OPTICS LETTERS, 2007, 32 (15) :2188-2190
[8]   Hyperosmotic chemical agent's effect on in vivo cerebral blood flow revealed by laser speckle [J].
Cheng, HY ;
Luo, QM ;
Zeng, SQ ;
Chen, SB ;
Luo, WH ;
Gong, H .
APPLIED OPTICS, 2004, 43 (31) :5772-5777
[9]   Modified laser speckle imaging method with improved spatial resolution [J].
Cheng, HY ;
Luo, QM ;
Zeng, SQ ;
Chen, SB ;
Cen, J ;
Gong, H .
JOURNAL OF BIOMEDICAL OPTICS, 2003, 8 (03) :559-564
[10]   Laser speckle imaging for monitoring blood flow dynamics in the in vivo rodent dorsal skin fold model [J].
Choi, B ;
Kang, NM ;
Nelson, JS .
MICROVASCULAR RESEARCH, 2004, 68 (02) :143-146