Simplified laser-speckle-imaging analysis method and its application to retinal blood flow imaging

被引:120
作者
Cheng, Haiying [1 ]
Duong, Timothy Q. [1 ]
机构
[1] Emory Univ, Yerkes Imaging Ctr, Dept Neurol, Atlanta, GA 30329 USA
关键词
D O I
10.1364/OL.32.002188
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Laser speckle imaging (LSI) is widely used to study blood flow at high spatiotemporal resolution. Several papers recently pointed out that the commonly used LSI equation involves an approximation that could result in incorrect data analysis. We investigated the impact of such an approximation and introduced a simplified analysis method to improve computation time. Flow phantom studies were performed for validation. Moreover, we demonstrated a novel LSI application by imaging blood flow of rat retinas under normal and physiologic-challenge conditions. Because blood-flow abnormality is implicated in many retinal diseases, LSI could provide valuable physiologic, and potentially diagnostic, information. (C) 2007 Optical Society of America.
引用
收藏
页码:2188 / 2190
页数:3
相关论文
共 14 条
[1]   Speckle-visibility spectroscopy: A tool to study time-varying dynamics [J].
Bandyopadhyay, R ;
Gittings, AS ;
Suh, SS ;
Dixon, PK ;
Durian, DJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (09)
[2]   Intrinsic brain activity triggers trigeminal meningeal afferents in a migraine model [J].
Bolay, H ;
Reuter, U ;
Dunn, AK ;
Huang, ZH ;
Boas, DA ;
Moskowitz, MA .
NATURE MEDICINE, 2002, 8 (02) :136-142
[3]   MODEL FOR LASER DOPPLER MEASUREMENTS OF BLOOD-FLOW IN TISSUE [J].
BONNER, R ;
NOSSAL, R .
APPLIED OPTICS, 1981, 20 (12) :2097-2107
[4]   Efficient characterization of regional mesenteric blood flow by use of laser speckle imaging [J].
Cheng, HY ;
Luo, QM ;
Wang, Z ;
Gong, H ;
Chen, SB ;
Liang, WX ;
Zeng, SQ .
APPLIED OPTICS, 2003, 42 (28) :5759-5764
[5]   Laser speckle imaging of blood flow in microcirculation [J].
Cheng, HY ;
Luo, QM ;
Liu, Q ;
Lu, QA ;
Gong, H ;
Zeng, SQ .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (07) :1347-1357
[6]  
CLERMONT AC, 1994, INVEST OPHTH VIS SCI, V35, P981
[7]   CONTINUOUS MEASUREMENT OF CEREBRAL CORTICAL BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY IN A RAT STROKE MODEL [J].
DIRNAGL, U ;
KAPLAN, B ;
JACEWICZ, M ;
PULSINELLI, W .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1989, 9 (05) :589-596
[8]   Dynamic imaging of cerebral blood flow using laser speckle [J].
Dunn, AK ;
Bolay, T ;
Moskowitz, MA ;
Boas, DA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2001, 21 (03) :195-201
[9]   FLOW VISUALIZATION BY MEANS OF SINGLE-EXPOSURE SPECKLE PHOTOGRAPHY [J].
FERCHER, AF ;
BRIERS, JD .
OPTICS COMMUNICATIONS, 1981, 37 (05) :326-330
[10]  
Goodman J., 2000, Statistical Optics