Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study

被引:654
作者
Ciatto, Stefano [1 ,2 ]
Houssami, Nehmat [3 ]
Bernardi, Daniela [1 ]
Caumo, Francesca [2 ]
Pellegrini, Marco [1 ]
Brunelli, Silvia [2 ]
Tuttobene, Paola [1 ]
Bricolo, Paola [2 ]
Fanto, Carmine [1 ]
Valentini, Marvi [1 ]
Montemezzi, Stefania [2 ]
Macaskill, Petra [3 ]
机构
[1] Azienda Prov Serv Sanit, UO Senol Clin & Screening Mammog, Dept Diagnost, Trento, Italy
[2] Ctr Prevenz Senol, Verona, Italy
[3] Univ Sydney, Sch Publ Hlth, Sydney Med Sch, Screening & Test Evaluat Program, Sydney, NSW 2006, Australia
基金
英国医学研究理事会;
关键词
D O I
10.1016/S1470-2045(13)70134-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Digital breast tomosynthesis with 3D images might overcome some of the limitations of conventional 2D mammography for detection of breast cancer. We investigated the effect of integrated 2D and 3D mammography in population breast-cancer screening. Methods Screening with Tomosynthesis OR standard Mammography (STORM) was a prospective comparative study. We recruited asymptomatic women aged 48 years or older who attended population-based breast-cancer screening through the Trento and Verona screening services (Italy) from August, 2011, to June, 2012. We did screen-reading in two sequential phases-2D only and integrated 2D and 3D mammography-yielding paired data for each screen. Standard double-reading by breast radiologists determined whether to recall the participant based on positive mammography at either screen read. Outcomes were measured from final assessment or excision histology. Primary outcome measures were the number of detected cancers, the number of detected cancers per 1000 screens, the number and proportion of false positive recalls, and incremental cancer detection attributable to integrated 2D and 3D mammography. We compared paired binary data with McNemar's test. Findings 7292 women were screened (median age 58 years [IQR 54-63]). We detected 59 breast cancers (including 52 invasive cancers) in 57 women. Both 2D and integrated 2D and 3D screening detected 39 cancers. We detected 20 cancers with integrated 2D and 3D only versus none with 2D screening only (p<0.0001). Cancer detection rates were 5.3 cancers per 1000 screens (95% CI 3.8-7.3) for 2D only, and 8.1 cancers per 1000 screens (6.2-10.4) for integrated 2D and 3D screening. The incremental cancer detection rate attributable to integrated 2D and 3D mammography was 2.7 cancers per 1000 screens (1.7-4.2). 395 screens (5.5%; 95% CI 5.0-6.0) resulted in false positive recalls: 181 at both screen reads, and 141 with 2D only versus 73 with integrated 2D and 3D screening (p<0.0001). We estimated that conditional recall (positive integrated 2D and 3D mammography as a condition to recall) could have reduced false positive recalls by 17.2% (95% CI 13.6-21.3) without missing any of the cancers detected in the study population. Interpretation Integrated 2D and 3D mammography improves breast-cancer detection and has the potential to reduce false positive recalls. Randomised controlled trials are needed to compare integrated 2D and 3D mammography with 2D mammography for breast cancer screening.
引用
收藏
页码:583 / 589
页数:7
相关论文
共 23 条
[1]  
American College of Radiology, 2003, ACR BI RADS BREAST I
[2]   The breast cancer screening debate: closing a chapter? [J].
不详 .
LANCET, 2012, 380 (9855) :1714-1714
[3]   Breast cancer screening: the questions answered [J].
Autier, Philippe ;
Esserman, Laura J. ;
Flowers, Chris I. ;
Houssami, Nehmat .
NATURE REVIEWS CLINICAL ONCOLOGY, 2012, 9 (10) :599-605
[4]   Breast Tomosynthesis: State-of-the-Art and Review of the Literature [J].
Baker, Jay A. ;
Lo, Joseph Y. .
ACADEMIC RADIOLOGY, 2011, 18 (10) :1298-1310
[5]   Application of breast tomosynthesis in screening: incremental effect on mammography acquisition and reading time [J].
Bernardi, D. ;
Ciatto, S. ;
Pellegrini, M. ;
Anesi, V. ;
Burlon, S. ;
Cauli, E. ;
Depaoli, M. ;
Larentis, L. ;
Malesani, V. ;
Targa, L. ;
Baldo, P. ;
Houssami, N. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1020) :E1174-E1178
[6]   Prospective study of breast tomosynthesis as a triage to assessment in screening [J].
Bernardi, Daniela ;
Ciatto, Stefano ;
Pellegrini, Marco ;
Tuttobene, Paolina ;
Fanto', Carmine ;
Valentini, Marvi ;
Di Michele, Stefano ;
Peterlongo, Paolo ;
Houssami, Nehmat .
BREAST CANCER RESEARCH AND TREATMENT, 2012, 133 (01) :267-271
[7]   Effects of study methods and biases on estimates of invasive breast cancer overdetection with mammography screening: a systematic review [J].
Biesheuvel, Corne ;
Barratt, Alexandra ;
Howard, Kirsten ;
Houssami, Nehmat ;
Irwig, Les .
LANCET ONCOLOGY, 2007, 8 (12) :1129-1138
[8]   Confidence intervals for a ratio of binomial proportions based on paired data [J].
Bonett, Douglas G. ;
Price, Robert M. .
STATISTICS IN MEDICINE, 2006, 25 (17) :3039-3047
[9]   Analysis of interval cancers observed in an Italian mammography screening programme (2000-2006) [J].
Caumo, F. ;
Vecchiato, F. ;
Pellegrini, M. ;
Vettorazzi, M. ;
Ciatto, S. ;
Montemezzi, S. .
RADIOLOGIA MEDICA, 2009, 114 (06) :907-914
[10]   Clinical Digital Breast Tomosynthesis System: Dosimetric Characterization [J].
Feng, Steve Si Jia ;
Sechopoulos, Ioannis .
RADIOLOGY, 2012, 263 (01) :35-42