Application of breast tomosynthesis in screening: incremental effect on mammography acquisition and reading time

被引:106
作者
Bernardi, D. [2 ]
Ciatto, S. [2 ]
Pellegrini, M. [2 ]
Anesi, V. [2 ]
Burlon, S. [2 ]
Cauli, E. [2 ]
Depaoli, M. [2 ]
Larentis, L. [2 ]
Malesani, V. [2 ]
Targa, L. [2 ]
Baldo, P. [2 ]
Houssami, N. [1 ]
机构
[1] Univ Sydney, Sydney Med Sch, Sch Publ Hlth, Screening & Test Evaluat Program, Sydney, NSW 2006, Australia
[2] APSS, Dipartimento Radiodiagnost, UO Senol Clin & Screening Mammog, Trento, Italy
基金
英国医学研究理事会;
关键词
CANCER; PERFORMANCE; OBSERVER; DENSITY; WOMEN;
D O I
10.1259/bjr/19385909
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to supplement the paucity of information available on logistical aspects of the application of three-dimensional (3D) mammography in breast screening. Methods: We prospectively examined the effect on radiographers' and radiologists' workload of implementing 3D mammography in screening by comparing image acquisition time and screen-reading time for two-dimensional (2D) mammography with that of combined 2D+3D mammography. Radiologists' accuracy was also calculated. Results: Average acquisition time (measured from start of first-view breast positioning to compression release at completion of last view) for seven radiographers, based on 20 screening examinations, was longer for 2D+3D (4 min 3 s; range 3 min 53 s-4 min 18 s) than 2D mammography (3 min 13 s; range 3 min 0 s-3 min 26 s; p<0.01). Average radiologists' reading time per screening examination (three radiologists reading case-mix of 100 screens: 10 cancers, 90 controls) was longer for 2D+3D (77 s; range 60-90 s) than for 2D mammography (33 s; range 25-46 s; p<0.01). 2D+3D screen-reading was associated with detection of more cancers and with substantially fewer recalls than 2D mammography alone. Conclusion: Relative to standard 2D mammography, combined 2D+3D mammography prolongs image acquisition time and screen-reading time (at initial implementation), and appears to be associated with improved screening accuracy. Advances in knowledge: These findings provide relevant information to guide larger trials of integrated 3D mammography (2D+3D) and its potential implementation into screening practice.
引用
收藏
页码:E1174 / E1178
页数:5
相关论文
共 20 条
[1]   Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings [J].
Andersson, Ingvar ;
Ikeda, Debra M. ;
Zackrisson, Sophia ;
Ruschin, Mark ;
Svahn, Tony ;
Timberg, Pontus ;
Tingberg, Anders .
EUROPEAN RADIOLOGY, 2008, 18 (12) :2817-2825
[2]  
Ciatto S, 1999, Radiol Med, V98, P255
[3]  
Ciatto S, 2005, RADIOL MED, V109, P321
[4]   Breast density as a determinant of interval cancer at mammographic screening [J].
Ciatto, S ;
Visioli, C ;
Paci, E ;
Zappa, M .
BRITISH JOURNAL OF CANCER, 2004, 90 (02) :393-396
[5]   Evidence of the effect of adjunct ultrasound screening in women with mammography-negative dense breasts: Interval breast cancers at 1 year follow-up [J].
Corsetti, Vittorio ;
Houssami, Nehmat ;
Ghirardi, Marco ;
Ferrari, Aurora ;
Speziani, Michela ;
Bellarosa, Sergio ;
Remida, Giuseppe ;
Gasparotti, Cristina ;
Galligioni, Enzo ;
Ciatto, Stefano .
EUROPEAN JOURNAL OF CANCER, 2011, 47 (07) :1021-1026
[6]   The evidence base for breast cancer screening [J].
Glasziou, Paul ;
Houssami, Nehmat .
PREVENTIVE MEDICINE, 2011, 53 (03) :100-102
[7]   Digital breast tomosynthesis: A pilot observer study [J].
Good, Walter F. ;
Abrams, Gordon S. ;
Catullo, Victor J. ;
Chough, Denise M. ;
Ganott, Marie A. ;
Hakim, Christiane M. ;
Gur, David .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) :865-869
[8]   Tomosynthesis: Potential clinical role in breast Imaging [J].
Gur, David .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (03) :614-615
[9]   Digital Breast Tomosynthesis: Observer Performance Study [J].
Gur, David ;
Abrams, Gordon S. ;
Chough, Denise M. ;
Ganott, Marie A. ;
Hakim, Christiane M. ;
Perrin, Ronald L. ;
Rathfon, Grace Y. ;
Sumkin, Jules H. ;
Zuley, Margarita L. ;
Bandos, Andriy I. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (02) :586-591
[10]   EFFICACY OF SCREENING MAMMOGRAPHY - A METAANALYSIS [J].
KERLIKOWSKE, K ;
GRADY, D ;
RUBIN, SM ;
SANDROCK, C ;
ERNSTER, VL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 273 (02) :149-154