A PROSPECTIVE RANDOMIZED CROSS-OVER COMPARISON OF MONOPHASIC AND BIPHASIC DEFIBRILLATION USING NONTHORACOTOMY LEAD CONFIGURATIONS IN HUMANS

被引:46
作者
BLOCK, M
HAMMEL, D
BOCKER, D
BORGGREFE, M
BUDDE, T
ISBRUCH, F
WIETHOLT, D
SCHELD, HH
BREITHARDT, G
机构
[1] HOSP WESTFAL WILHELMS UNIV MUNSTER,DEPT CARDIOL ANGIOL,MUNSTER,GERMANY
[2] DEPT CARDIOVASC SURG,MUNSTER,GERMANY
[3] INST RES ATERIOSCLEROSIS,MUNSTER,GERMANY
关键词
IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; VENTRICULAR FIBRILLATION; DEFIBRILLATION WAVE-FORM; ENDOCARDIAL DEFIBRILLATION; DEFIBRILLATION THRESHOLD;
D O I
10.1111/j.1540-8167.1994.tb01299.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: For current implantable defibrillators, the nonthoracotomy approach to implantation fails in a substantial number of patients. In a prospective randomized cross-over study the defibrillation efficacy of a standard monophasic and a new biphasic waveform was compared for different lead configurations. Methods and Results: Intraoperatively, in 79 patients receiving nonthoracotomy defibrillation leads, the defibrillation threshold was determined in the initial lead configuration for the mono-and biphasic waveform. In each patient, both waveforms were used alternately with declining energies (20, 15, 10, 5 J) until failure of defibrillation occurred. Three different initial lead configurations were tested in different, consecutive, nonrandomized patients using a bipolar endocardial defibrillation lead alone (A; n = 36) or in combination with a subcutaneous defibrillation patch (B; n = 24) or array (C; n = 19) lead. The lowest successful defibrillation energy with the biphasic waveform was less than, equal to, or higher than with the monophasic waveform in 64%, 28%, and 8% of patients, respectively, and on average significantly lower with the biphasic waveform for all three lead configurations (A: 11.3 +/- 4.4 J vs 14.5 +/- 4.5 J; B: 9.7 +/- 4.7 J vs 15.1 +/- 4.5 J; C: 7.9 +/- 4.5 J vs 12.4 +/- 4.9 J). Defibrillation efficacy at 20 J was significantly improved by the biphasic waveform (91 % vs 76 %). Conclusion: In combination with nonthoracotomy defibrillation leads, the biphasic waveform of a new implantable cardioverter defibrillator showed superior defibrillation efficacy in comparison to the standard monophasic waveform. Defibrillation thresholds were improved for lead systems with and without a subcutaneous patch or array lead.
引用
收藏
页码:581 / 590
页数:10
相关论文
共 31 条
[1]   A SIMPLIFIED, SINGLE-LEAD UNIPOLAR TRANSVENOUS CARDIOVERSION-DEFIBRILLATION SYSTEM [J].
BARDY, GH ;
JOHNSON, G ;
POOLE, JE ;
DOLACK, GL ;
KUDENCHUK, PJ ;
KELSO, D ;
MITCHELL, R ;
MEHRA, R ;
HOFER, B .
CIRCULATION, 1993, 88 (02) :543-547
[2]   A PROSPECTIVE RANDOMIZED EVALUATION OF BIPHASIC VERSUS MONOPHASIC WAVEFORM PULSES ON DEFIBRILLATION EFFICACY IN HUMANS [J].
BARDY, GH ;
IVEY, TD ;
ALLEN, MD ;
JOHNSON, G ;
MEHRA, R ;
GREENE, HL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :728-733
[3]   IMPLANTABLE TRANSVENOUS CARDIOVERTER-DEFIBRILLATORS [J].
BARDY, GH ;
HOFER, B ;
JOHNSON, G ;
KUDENCHUK, PJ ;
POOLE, JE ;
DOLACK, GL ;
GLEVA, M ;
MITCHELL, R ;
KELSO, D .
CIRCULATION, 1993, 87 (04) :1152-1168
[4]   ELECTRODE SYSTEM INFLUENCE ON BIPHASIC WAVE-FORM DEFIBRILLATION EFFICACY IN HUMANS [J].
BARDY, GH ;
TROUTMAN, C ;
JOHNSON, G ;
MEHRA, R ;
POOLE, JE ;
DOLACK, GL ;
KUDENCHUK, PJ ;
GARTMAN, DM .
CIRCULATION, 1991, 84 (02) :665-671
[5]  
BHANDARI AK, 1990, CIRCULATION, V86, P790
[6]   RESULTS AND REALISTIC EXPECTATIONS WITH TRANSVENOUS LEAD SYSTEMS [J].
BLOCK, M ;
HAMMEL, D ;
ISBRUCH, F ;
BORGGREFE, M ;
WIETHOLT, D ;
HACHENBERG, T ;
SCHELD, HH ;
BREITHARDT, G .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (04) :665-670
[7]  
BLOCK M, 1992, Journal of the American College of Cardiology, V19, p243A
[8]  
BLOCK M, 1993, PACE, V16, P1913
[9]   COMPARISON OF MONOPHASIC WITH SINGLE AND DUAL CAPACITOR BIPHASIC WAVEFORMS FOR NONTHORACOTOMY CANINE INTERNAL DEFIBRILLATION [J].
CHAPMAN, PD ;
VETTER, JW ;
SOUZA, JJ ;
WETHERBEE, JN ;
TROUP, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (01) :242-245
[10]   IMPROVED DEFIBRILLATION THRESHOLDS WITH LARGE CONTOURED EPICARDIAL ELECTRODES AND BIPHASIC WAVE-FORMS [J].
DIXON, EG ;
TANG, ASL ;
WOLF, PD ;
MEADOR, JT ;
FINE, MJ ;
CALFEE, RV ;
IDEKER, RE .
CIRCULATION, 1987, 76 (05) :1176-1184