A SIMPLIFIED, SINGLE-LEAD UNIPOLAR TRANSVENOUS CARDIOVERSION-DEFIBRILLATION SYSTEM

被引:180
作者
BARDY, GH
JOHNSON, G
POOLE, JE
DOLACK, GL
KUDENCHUK, PJ
KELSO, D
MITCHELL, R
MEHRA, R
HOFER, B
机构
[1] UNIV WASHINGTON HOSP, MAIL STOP RG-22, SEATTLE, WA 98195 USA
[2] UNIV WASHINGTON, DEPT SURG, DIV CARDIOVASC SURG, SEATTLE, WA 98195 USA
[3] UNIV WASHINGTON, DEPT MED, SEATTLE, WA 98195 USA
关键词
SUDDEN DEATH; VENTRICULAR FIBRILLATION; VENTRICULAR TACHYCARDIA; DEFIBRILLATION;
D O I
10.1161/01.CIR.88.2.543
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Transvenous implantable cardioverter-defibrillators provide significant advantages in the treatment of patients with life-threatening ventricular arrhythmias. However, present technology requires considerable electrophysiology expertise, multiple incisions, and long operative times for successful implementation. Methods and Results. In this study, we present a prototype of a new, easy-to-insert unipolar transvenous defibrillation system that has the reliability of epicardial defibrillation but the ease of pacemaker insertion. This system incorporates a single anodal right ventricular defibrillation electrode using a 65% tilt biphasic pulse delivered to a 108-cm2 surface area pulse generator titanium alloy shell as an active cathode placed in a left infraclavicular pocket. Testing of this system was performed before implantation of a standard nonthoracotomy-transvenous defibrillation system in 40 consecutive patients with a history of ventricular tachycardia or fibrillation. The simplified unipolar single-lead system resulted in a defibrillation threshold of 9.3 +/- 6.0 J with 37 of 40 patients (93%) having a defibrillation threshold of less than 20 J. Moreover, the unipolar defibrillation system was efficiently used requiring only 3.4 +/- 0.8 ventricular fibrillation inductions to measure the defibrillation threshold and 100 +/- 28 minutes to implement. Conclusions. This new unipolar transvenous defibrillation system is as simple to insert as a pacemaker, requires few ventricular fibrillation inductions, demands less technical expertise, and provides defibrillation at energy levels comparable to that reported with epicardial lead systems. It should substantially reduce the morbidity, time, and cost of defibrillator implantation.
引用
收藏
页码:543 / 547
页数:5
相关论文
共 46 条
[1]  
AKHTAR M, 1992, CIRCULATION, V85, P131
[2]  
[Anonymous], 1989, NEW ENGL J MED, V321, P406
[3]  
BACH SM, 1989, J AM COLL CARDIOL, V13, P65
[4]   A PROSPECTIVE, RANDOMIZED EVALUATION OF EFFECT OF VENTRICULAR-FIBRILLATION DURATION ON DEFIBRILLATION THRESHOLDS IN HUMANS [J].
BARDY, GH ;
IVEY, TD ;
ALLEN, M ;
JOHNSON, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) :1362-1366
[5]   EVALUATION OF ELECTRODE POLARITY ON DEFIBRILLATION EFFICACY [J].
BARDY, GH ;
IVEY, TD ;
ALLEN, MD ;
JOHNSON, G ;
GREENE, HL .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (07) :433-437
[6]   CLINICAL-EXPERIENCE WITH A TIERED-THERAPY, MULTIPROGRAMMABLE ANTIARRHYTHMIA DEVICE [J].
BARDY, GH ;
TROUTMAN, C ;
POOLE, JE ;
KUDENCHUK, PJ ;
DOLACK, GL ;
JOHNSON, G ;
HOFER, B .
CIRCULATION, 1992, 85 (05) :1689-1698
[7]   TRANSVENOUS DEFIBRILLATION IN HUMANS VIA THE CORONARY SINUS [J].
BARDY, GH ;
ALLEN, MD ;
MEHRA, R ;
JOHNSON, G ;
FELDMAN, S ;
GREENE, HL ;
IVEY, TD .
CIRCULATION, 1990, 81 (04) :1252-1259
[8]   A PROSPECTIVE RANDOMIZED EVALUATION OF BIPHASIC VERSUS MONOPHASIC WAVEFORM PULSES ON DEFIBRILLATION EFFICACY IN HUMANS [J].
BARDY, GH ;
IVEY, TD ;
ALLEN, MD ;
JOHNSON, G ;
MEHRA, R ;
GREENE, HL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :728-733
[9]   IMPLANTABLE TRANSVENOUS CARDIOVERTER-DEFIBRILLATORS [J].
BARDY, GH ;
HOFER, B ;
JOHNSON, G ;
KUDENCHUK, PJ ;
POOLE, JE ;
DOLACK, GL ;
GLEVA, M ;
MITCHELL, R ;
KELSO, D .
CIRCULATION, 1993, 87 (04) :1152-1168
[10]   AN EFFECTIVE AND ADAPTABLE TRANSVENOUS DEFIBRILLATION SYSTEM USING THE CORONARY SINUS IN HUMANS [J].
BARDY, GH ;
ALLEN, MD ;
MEHRA, R ;
JOHNSON, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (04) :887-895