OPTIMAL DETECTION, CLASSIFICATION, AND SUPERPOSITION RESOLUTION IN NEURAL WAVE-FORM RECORDINGS

被引:76
作者
BANKMAN, IN [1 ]
JOHNSON, KO [1 ]
SCHNEIDER, W [1 ]
机构
[1] JOHNS HOPKINS UNIV,DEPT NEUROSCI,BALTIMORE,MD 21205
关键词
D O I
10.1109/10.238472
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effects of noise autocorrelation on neural waveform recognition (detection, classification, and superposition resolution) are investigated in this study using microelectrode recordings from the cortex of a monkey. Optimal waveform recognition is accomplished by passing the data through a whitening filter before matched filtering for detection or template matching for classification and superposition resolution. Template matching without whitening requires about 40% higher signal-to-noise ratio than template matching with whitening for comparable classification and superposition resolution. The comparable difference for detection is 15%.
引用
收藏
页码:836 / 841
页数:6
相关论文
共 23 条
[11]  
Ljung L., 1999, SYSTEM IDENTIFICATIO
[12]   HIGH-RESOLUTION ALIGNMENT OF SAMPLED WAVEFORMS [J].
MCGILL, KC ;
DORFMAN, LJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (06) :462-468
[13]   ON-LINE MULTI-UNIT SORTING WITH RESOLUTION OF SUPERPOSITION POTENTIALS [J].
PROCHAZK.VJ ;
KORNHUBE.HH .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1973, 34 (01) :91-93
[14]   UNSUPERVISED WAVEFORM CLASSIFICATION FOR MULTI-NEURON RECORDINGS - A REAL-TIME, SOFTWARE-BASED SYSTEM .1. ALGORITHMS AND IMPLEMENTATION [J].
SALGANICOFF, M ;
SARNA, M ;
SAX, L ;
GERSTEIN, GL .
JOURNAL OF NEUROSCIENCE METHODS, 1988, 25 (03) :181-187
[15]   UNSUPERVISED WAVEFORM CLASSIFICATION FOR MULTI-NEURON RECORDINGS - A REAL-TIME, SOFTWARE-BASED SYSTEM .2. PERFORMANCE COMPARISON TO OTHER SORTERS [J].
SARNA, MF ;
GOCHIN, P ;
KALTENBACH, J ;
SALGANICOFF, M ;
GERSTEIN, GL .
JOURNAL OF NEUROSCIENCE METHODS, 1988, 25 (03) :189-196
[16]   COMPUTER-SEPARATION OF MULTI-UNIT NEUROELECTRIC DATA - A REVIEW [J].
SCHMIDT, EM .
JOURNAL OF NEUROSCIENCE METHODS, 1984, 12 (02) :95-111
[17]   A REAL-TIME MULTIPROCESSOR SYSTEM FOR ACQUISITION OF MULTICHANNEL NEURAL DATA [J].
SMITH, SR ;
WHEELER, BC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (10) :875-877
[18]   AUTOMATIC DECOMPOSITION OF SELECTIVE NEEDLE-DETECTED MYOELECTRIC SIGNALS [J].
STASHUK, D ;
DEBRUIN, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (01) :1-10
[19]   AN ALGORITHM FOR SEQUENTIAL SIGNAL ESTIMATION AND SYSTEM-IDENTIFICATION FOR EMG SIGNALS [J].
STUDER, RM ;
DEFIGUEIREDO, RJP ;
MOSCHYTZ, GS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (03) :285-295
[20]   INTELLIGENT SOFTWARE FOR SPIKE SEPARATION IN MULTIUNIT RECORDINGS [J].
VIBERT, JF ;
ALBERT, JN ;
COSTA, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1987, 25 (04) :366-372