LIQUID-CHROMATOGRAPHY WITH PHOTODIODE-ARRAY SPECTROPHOTOMETRIC DETECTION IN THE FORENSIC SCIENCES

被引:28
作者
LOGAN, BK
机构
[1] Washington State Toxicology Laboratory, Department of Laboratory Medicine, University of Washington, Seattle
关键词
LIQUID CHROMATOGRAPHY; UV-VISIBLE SPECTROPHOTOMETRY; FORENSIC ANALYSIS; PHOTODIODE ARRAY DETECTION; STREET DRUG ANALYSIS; TOXICOLOGY;
D O I
10.1016/0003-2670(94)85120-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Liquid chromatography (LC) is used in forensic laboratories for numerous applications including examination of drugs and poisons, plastics and polymers, oils, hydrocarbons, cosmetics, inks, dyes and pigments. LC with photodiode array detection (PDA) is a hybrid technique which can provide complete UV-visible spectral information on a given peak in a chromatogram, enabling determinations of peak purity to be made, and identification of unknown peaks to be assigned by library searches of spectral information in combination with retention behavior. These are valuable features normally associated with gas chromatography-mass spectrometry. The additional information available on each peak makes LC-PDA a particularly attractive technique for the forensic laboratory where higher levels of certainty are often demanded in test results. This paper reviews some of those applications for LC-PDA in the forensic sciences, including drug screening, drug and pharmaceutical analysis, differentiation of inks, identification of pesticides, fungi, quality control testing and profiling of cosmetics, street drugs and profiling of other complex mixtures. The practical and technical limitations of the technique are explored and its place in the hierarchy of methods available in forensic laboratories is evaluated.
引用
收藏
页码:111 / 122
页数:12
相关论文
共 61 条
[31]   DIRECT ANALYSIS OF ANTICONVULSANT DRUGS IN VITREOUS-HUMOR BY HPLC USING A COLUMN SWITCHING TECHNIQUE [J].
LOGAN, BK ;
STAFFORD, DT .
FORENSIC SCIENCE INTERNATIONAL, 1989, 41 (1-2) :125-134
[32]  
LOGAN BK, 1989, J FORENSIC SCI, V34, P553
[33]  
LOGAN BK, 1990, J FORENSIC SCI, V35, P1303
[34]   RAPID SCREENING FOR 100 BASIC DRUGS AND METABOLITES IN URINE USING CATION-EXCHANGE SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH DIODE-ARRAY DETECTION [J].
LOGAN, BK ;
STAFFORD, DT ;
TEBBETT, IR ;
MOORE, CM .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1990, 14 (03) :154-159
[35]   USE OF NARROW-BORE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR MICROANALYSIS OF PROTEIN-STRUCTURE [J].
LU, HS ;
LAI, PH .
JOURNAL OF CHROMATOGRAPHY, 1986, 368 (02) :215-231
[36]   ANALYSIS OF MANUFACTURING BY-PRODUCTS AND IMPURITIES IN ILLICIT COCAINE VIA HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND PHOTODIODE ARRAY DETECTION [J].
LURIE, IS ;
MOORE, JM ;
COOPER, DA ;
KRAM, TC .
JOURNAL OF CHROMATOGRAPHY, 1987, 405 :273-281
[37]   PRESERVATIVES BASED ON METHYLISOTHIAZOLONES IN COSMETIC PRODUCTS - THEORY AND ANALYSIS .1. AGENTS, CHEMICAL ASPECTS, METHODS FOR DETECTION AND IDENTIFICATION .2. QUANTIFICATION, METHODS FOR ISOLATION AND DETERMINATION IN COSMETICS [J].
MATISSEK, R .
ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1986, 183 (04) :273-289
[38]  
MILLS T, 1987, INSTRUMENTAL ANAL DR
[39]   TOXICOLOGICAL SCREENING FOR BENZODIAZEPINES IN URINE - EMITST VERSUS HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTODIODE ARRAY DETECTION [J].
MINDER, EI ;
SCHAUBHUT, R ;
SIMMLER, F .
TOXICOLOGY LETTERS, 1989, 45 (01) :93-99
[40]   TOXICITY IN A CASE OF ACUTE AND MASSIVE OVERDOSE OF CHLORDIAZEPOXIDE AND ITS CORRELATION TO BLOOD-CONCENTRATION [J].
MINDER, EI .
JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 1989, 27 (1-2) :117-127