CHANGES IN T-2-ASTERISK-WEIGHTED IMAGES DURING HYPEROXIA DIFFERENTIATE TUMORS FROM NORMAL TISSUE

被引:43
作者
KUPERMAN, VY
RIVER, JN
LEWIS, MZ
LUBICH, LM
KARCZMAR, GS
机构
[1] UNIV CHICAGO,DEPT RADIOL,CHICAGO,IL 60637
[2] UNIV CHICAGO,DEPT RADIAT & CELLULAR ONCOL,CHICAGO,IL 60637
关键词
MAGNETIC RESONANCE; TUMORS; HYPEROXIA;
D O I
10.1002/mrm.1910330306
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Experiments were performed to determine whether changes in T-2*-weighted MR images during and after hyperoxia differentiate tumors from normal tissue. Mammary adenocarcinomas implanted in the right hind limbs of rats were studied. Gradient echo images were obtained at 2 Tesla with an evolution time of 20 ms and a recycle time of 1 s. Breathing gas was either air or 100% O-2. Significant increases in image intensity were observed in tumor centers and rims during hyperoxia while much smaller changes were detected in the surrounding muscle. The relaxation rate (1/T-2*) in tumors decreased during hyperoxia by an average of 2.5 +/- 1.0 s(-1), while in muscle the average change was an increase of 0.6 +/- 2.1 s(-1). The largest decreases in relaxation rate were detected in non-necrotic tumor regions with relatively low density of blood vessels. Immediately following hyperoxia significant decreases in intensity were detected in tumors while much smaller decreases were detected in the surrounding muscle.
引用
收藏
页码:318 / 325
页数:8
相关论文
共 25 条
[1]  
BANDETTINI PA, 1992, J MAGN RESON IMAGING, V2, P76
[2]  
BHUJWALLA ZM, 1993, 12 ANN M SOC MAGN RE, P142
[3]   MR CONTRAST DUE TO MICROSCOPICALLY HETEROGENEOUS MAGNETIC-SUSCEPTIBILITY - NUMERICAL SIMULATIONS AND APPLICATIONS TO CEREBRAL PHYSIOLOGY [J].
FISEL, CR ;
ACKERMAN, JL ;
BUXTON, RB ;
GARRIDO, L ;
BELLIVEAU, JW ;
ROSEN, BR ;
BRADY, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :336-347
[4]  
GULLINO PM, 1967, CANCER RES, V27, P1020
[5]  
HILF R, 1965, CANCER RES, V25, P286
[6]   MEASUREMENT OF REGIONAL BLOOD OXYGENATION AND CEREBRAL HEMODYNAMICS [J].
HOPPEL, BE ;
WEISSKOFF, RM ;
THULBORN, KR ;
MOORE, JB ;
KWONG, KK ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (06) :715-723
[7]   MAGNETIC-RESONANCE MEASUREMENT OF RESPONSE TO HYPEROXIA DIFFERENTIATES TUMORS FROM NORMAL TISSUE AND MAY BE SENSITIVE TO OXYGEN-CONSUMPTION [J].
KARCZMAR, GS ;
KUPERMAN, VY ;
RIVER, JN ;
LEWIS, MZ ;
LIPTON, MJ .
INVESTIGATIVE RADIOLOGY, 1994, 29 :S161-S163
[8]  
KARCZMAR GS, IN PRESS J MAGN RESO
[9]  
KARCZMAR GS, IN PRESS NMR BIOMED
[10]  
KARCZMAR GS, 1992, 11TH P SMRM ANN M BE, P830