MR CONTRAST DUE TO MICROSCOPICALLY HETEROGENEOUS MAGNETIC-SUSCEPTIBILITY - NUMERICAL SIMULATIONS AND APPLICATIONS TO CEREBRAL PHYSIOLOGY

被引:297
作者
FISEL, CR
ACKERMAN, JL
BUXTON, RB
GARRIDO, L
BELLIVEAU, JW
ROSEN, BR
BRADY, TJ
机构
[1] HARVARD UNIV,SCH MED,BOSTON,MA 02114
[2] UNIV CALIF SAN DIEGO,DEPT RADIOL,SAN DIEGO,CA 92103
关键词
D O I
10.1002/mrm.1910170206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We calculate the effects of subvoxel variations in magnetic susceptibility on MR image intensity for spin‐echo (SE) and gradient‐echo (GE) experiments for a range of microscopic physical parameters. The model used neglects the overlap of gradients from one magnetic inclusion to the next, and so is valid for low volume fractions and weak perturbations of the magnetic field. Transverse relaxation is predicted to deviate significantly from linear exponential decay in both SE and GE at a particle radius of 2.5 μm. Calculated changes in transverse relaxation rates for SE and GE increase linearly with volume fraction of high‐susceptibility regions of 5 μm diameter, but increase with about the 3/2 power of volume fraction of regions with 15 μm spacing between centers. This sensitivity to the actual size and spacing of magnetized regions may allow them to be measured on the basis of contrast, without being resolved in images. GE and SE decay rates are approximately twice as sensitive to long cylinders of 5 μm diameter than to spheres of the same size, for diffusion constants of 2.5 μm2/ms. Calculated changes in transverse decay rates increase with approximately the square of field and susceptibility variation for 5‐μm spheres and a diffusion constant of 2.5 μm2/ms. This exponent is smaller for cylindrical magnetized regions of the same size, and also depends on the diffusion constant. We discuss possible applications of our theoretical results to the analysis of the effects of high‐susceptibility contrast agents in brain. Experimental data from the literature are compared with calculated signal changes according to the model. The monotonic dependence of decay rates on the volume of distribution of the contrast agent suggests that cerebral blood volume and flow could be measured using MR contrast. © 1991 Academic Press, Inc. Copyright © 1991 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:336 / 347
页数:12
相关论文
共 38 条
[1]  
AHN CB, 1986, MED PHYS, V13
[2]  
BELLIVEAU JW, 1986, 5TH ANN M SOC MAGN R
[3]   CEREBRAL BLOOD-FLOW AND OXYGEN-CONSUMPTION IN THE RAT-BRAIN DURING EXTREME HYPERCARBIA [J].
BERNTMAN, L ;
DAHLGREN, N ;
SIESJO, BK .
ANESTHESIOLOGY, 1979, 50 (04) :299-305
[4]   NUCLEAR MAGNETIC-RESONANCE TECHNOLOGY FOR MEDICAL STUDIES [J].
BUDINGER, TF ;
LAUTERBUR, PC .
SCIENCE, 1984, 226 (4672) :288-298
[5]   CONTRAST IN RAPID MR IMAGING - T1-WEIGHTED AND T2-WEIGHTED IMAGING [J].
BUXTON, RB ;
EDELMAN, RR ;
ROSEN, BR ;
WISMER, GL ;
BRADY, TJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :7-16
[6]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[7]   A MATHEMATICAL-MODEL OF DIAMAGNETIC LINE BROADENING IN LUNG-TISSUE AND SIMILAR HETEROGENEOUS SYSTEMS - CALCULATIONS AND MEASUREMENTS [J].
CASE, TA ;
DURNEY, CH ;
AILION, DC ;
CUTILLO, AG ;
MORRIS, AH .
JOURNAL OF MAGNETIC RESONANCE, 1987, 73 (02) :304-314
[8]  
CHIEN D, 1988, 7TH ANN M SOC MAGN R
[9]   FERROMAGNETIC PARTICLES AS CONTRAST AGENTS FOR MAGNETIC-RESONANCE-IMAGING OF LIVER AND SPLEEN [J].
DIAS, MHM ;
LAUTERBUR, PC .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (02) :328-330
[10]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194