Reliability of gait speed measured by a timed walking test in patients one year after stroke

被引:116
作者
Green, J
Forster, A
Young, J
机构
[1] Bradford Community NHS Trust, Bradford, W Yorkshire, England
[2] Bradford Hosp NHS Trust, Dept Hlth Care Elderly, Bradford, W Yorkshire, England
关键词
D O I
10.1191/0269215502cr495oa
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To assess the reliability of gait speed in late-stage stroke patients. Design: Test-retest reliability of three timed walks to 10 metres repeated during two assessments one week apart. Setting: The patient's home. Subjects: Twenty-two stroke patients with mobility problems more than one year after stroke. Main outcome measure: Gait speed measured in seconds taken to walk 10 metres. Statistical analysis: Intraclass correlations (ICCs) with 95% confidence interval (Cl) and the Bland and Altman method for assessing agreement by calculating the mean difference between measurements ((d) over bar), the 95% CI for (d) over bar; the standard deviation of the difference (SDdiff); a reliability coefficient and the 95% limits of agreement. Results: There was a trend for decreased times taken to walk 10 metres both within each assessment and between assessments. ICCs for within-assessment reliability were 0.95-0.99. The (d) over bar (SDdiff) for the second and third walks for assessment 1 was -1.00 (2.63) seconds and for assessment 2 was -0.70 (1.58) seconds. The reliability coefficient was 5.26 for assessment 1 and 3.17 for assessment 2. ICCs for between-assessment reliability were 0.87-0.88. The (d) over bar (SDdiff) for the comparison of the third walks at assessment 1 and assessment 2 was -0.90 (5.01) seconds. The reliability coefficient was 10.02 and the 95% limits of agreement were -10.92 to +9.12 seconds. Conclusion: Within-assessment gait speed measured at home is highly reliable. The between-assessment reliability of gait speed measurement is less reliable but comparable with other studies.
引用
收藏
页码:306 / 314
页数:9
相关论文
共 31 条
[21]  
OZGIRGIN N, 1993, SCAND J REHABIL MED, V25, P51
[22]   THE TIMED UP AND GO - A TEST OF BASIC FUNCTIONAL MOBILITY FOR FRAIL ELDERLY PERSONS [J].
PODSIADLO, D ;
RICHARDSON, S .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1991, 39 (02) :142-148
[23]   Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses [J].
Rankin, G ;
Stokes, M .
CLINICAL REHABILITATION, 1998, 12 (03) :187-199
[24]   INTRACLASS CORRELATIONS - USES IN ASSESSING RATER RELIABILITY [J].
SHROUT, PE ;
FLEISS, JL .
PSYCHOLOGICAL BULLETIN, 1979, 86 (02) :420-428
[25]   Walking speed on parquetry and carpet after stroke: effect of surface and retest reliability [J].
Stephens, JM ;
Goldie, PA .
CLINICAL REHABILITATION, 1999, 13 (02) :171-181
[26]   Ten-metre walk, with or without a turn? [J].
van Herk, IEH ;
Arendzen, JH ;
Rispens, P .
CLINICAL REHABILITATION, 1998, 12 (01) :30-35
[27]  
WADE D, 2000, NATL CLIN GUIDELINES, P54
[28]  
WADE DT, 1987, SCAND J REHABIL MED, V19, P25
[29]   PHYSIOTHERAPY INTERVENTION LATE AFTER STROKE AND MOBILITY [J].
WADE, DT ;
COLLEN, FM ;
ROBB, GF ;
WARLOW, CP .
BRITISH MEDICAL JOURNAL, 1992, 304 (6827) :609-613
[30]  
Wade DT, 1992, MEASUREMENT NEUROLOG