Three-dimensional intravascular ultrasonic volumetric quantification of stent recoil and neointimal formation of two new generation tubular stents

被引:37
作者
Costa, MA
Sabate, M
Kay, IP
de Feyter, PJ
Kozuma, K
Serrano, P
de Valk, V
Albertal, M
Ligthart, JMR
Disco, C
Foley, DP
Serruys, PW
机构
[1] Univ Hosp Dijkzigt, Dept Intervent Cardiol, Thoraxctr BD418, NL-3015 GD Rotterdam, Netherlands
[2] Cardialysis BV, Rotterdam, Netherlands
关键词
D O I
10.1016/S0002-9149(99)00655-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Currently, several different designs of coronary stents are available. However, only a few of the new generation stents have been investigated in large randomized trials. Mechanical behavior of first-generation stents (Palmaz-Schatz, Gianturco-Roubin) may not be applied to the new designs. We investigated the chronic mechanical behavior (recoil) of 2 stents recently approved by the Food and Drug Administration (MULTILINK and NIR). Forty-eight patients with single-stent implantation (23 MULTILINK and 25 NIR) were assessed by means of volumetric 3-dimensional intravascular ultrasound analysis after the procedure and at 6-month follow-up. In addition, volumetric assessment of neointimal formation wets performed. No significant chronic stent recoil was detected in both groups (Delta MULTILINK stent volume: +5.6 +/- 41 mm(3) [p = NS] and Delta NIR stent volume + 2.1 +/- 26 mm(3) [p = NS]). A similar degree of neointimal formation at 6 months was observed between the 2 stents (MULTILINK 46 +/- 31.9 mm(3) vs NIR 39.9 +/- 27.6 mm(3), p = NS). In conclusion, these 2 second-generation tubular stents did not show chronic recoil and appeared to promote similar proliferative response after implantation in human coronary arteries. (C) 2000 by Excerpta Medica, Inc.
引用
收藏
页码:135 / 139
页数:5
相关论文
共 25 条
[1]  
Anzai H., 1996, European Heart Journal, V17, P518
[2]  
BEYAR R, 1997, FRONTIERS INTERVENTI, P69
[3]   In vivo validation of intravascular ultrasound length measurements using a motorized transducer pullback system [J].
Fuessl, RT ;
Mintz, GS ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Popma, JJ ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (12) :1115-&
[4]   QUANTITATIVE-ANALYSIS OF ELASTIC RECOIL AFTER BALLOON ANGIOPLASTY AND AFTER INTRACORONARY IMPLANTATION OF BALLOON-EXPANDABLE PALMAZ-SCHATZ STENTS [J].
HAUDE, M ;
ERBEL, R ;
ISSA, H ;
MEYER, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) :26-34
[5]   Acute and chronic effects of self-expanding nitinol stents in porcine coronary arteries [J].
Hong, MK ;
Beyar, R ;
Kornowski, R ;
Tio, FO ;
Bramwell, O ;
Leon, MB .
CORONARY ARTERY DISEASE, 1997, 8 (01) :45-48
[6]  
Itoh A, 1996, CATHETER CARDIO DIAG, V37, P334, DOI 10.1002/(SICI)1097-0304(199603)37:3<334::AID-CCD27>3.3.CO
[7]  
2-I
[8]  
KUTRYK MJB, 1999, CORONARY STENTING CU, P17
[9]  
LEON MB, 1993, CLIN USES PALMAZSCHA, P153
[10]   STUDY ON THE NUCLEAR-REACTIONS OF NB-93, TA-181, AND AU-197 INDUCED BY SECONDARY NEUTRONS IN 40 MEV/NUCLEON AR-40 ION COLLISIONS [J].
LI, WX ;
OHKUBO, Y ;
AMBE, S ;
KOBAYASHI, Y ;
IWAMOTO, M ;
MAEDA, H ;
AMBE, F .
CHEMISTRY LETTERS, 1994, (02) :277-280