Analytical aspects of mass spectrometry and proteomics

被引:38
作者
Mo, WJ
Karger, BL
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1016/S1367-5931(02)00379-4
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Mass spectrometry plays an essential role in proteomics analysis and research. In recent years, it has been increasingly recognized that a key to proteomics using mass spectrometry relies not only on the instrument itself, but also on the analytical strategies and front-end sample-handling techniques. The advances of separations and mass spectrometry are having an increasing impact on the discovery of disease biomarkers and the understanding of cellular processes.
引用
收藏
页码:666 / 675
页数:10
相关论文
共 123 条
[1]   The cell as a collection of protein machines: Preparing the next generation of molecular biologists [J].
Alberts, B .
CELL, 1998, 92 (03) :291-294
[2]   Axin-mediated CKI phosphorylation of β-catenin at Ser 45:: a molecular switch for the Wnt pathway [J].
Amit, S ;
Hatzubai, A ;
Birman, Y ;
Andersen, JS ;
Ben-Shushan, E ;
Mann, M ;
Ben-Neriah, Y ;
Alkalay, I .
GENES & DEVELOPMENT, 2002, 16 (09) :1066-1076
[3]   ISOLATION OF PHOSPHOPROTEINS BY IMMOBILIZED METAL (FE-3+) AFFINITY-CHROMATOGRAPHY [J].
ANDERSSON, L ;
PORATH, J .
ANALYTICAL BIOCHEMISTRY, 1986, 154 (01) :250-254
[4]   Matrix assisted laser desorption/ionization coupled with quadrupole/orthogonal acceleration time-of-flight mass spectrometry for protein discovery, identification, and structural analysis [J].
Baldwin, MA ;
Medzihradszky, KF ;
Lock, CM ;
Fisher, B ;
Settineri, TA ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1707-1720
[5]   Resolving isomeric peptide mixtures: A combined HPLC/ion mobility-TOFMS analysis of a 4000-component combinatorial library [J].
Barnes, CAS ;
Hilderbrand, AE ;
Valentine, SJ ;
Clemmer, DE .
ANALYTICAL CHEMISTRY, 2002, 74 (01) :26-36
[6]   Dynamic range expansion applied to mass spectrometry based on data-dependent selective ion ejection in capillary liquid chromatography Fourier transform ion cyclotron resonance for enhanced proteome characterization [J].
Belov, ME ;
Anderson, GA ;
Angell, NH ;
Shen, YF ;
Tolic, N ;
Udseth, HR ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5052-5060
[7]   A new technique for unbiased external ion accumulation in a quadrupole two-dimensional ion trap for electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry [J].
Belov, ME ;
Nikolaev, EN ;
Alving, K ;
Smith, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (14) :1172-1180
[8]   Controlled ion fragmentation in a 2-D quadrupole ion trap for external ion accumulation in ESI FTICR mass spectrometry [J].
Belov, ME ;
Gorshkov, MV ;
Udseth, HR ;
Smith, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (12) :1312-1319
[9]   Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer [J].
Belov, ME ;
Nikolaev, EN ;
Anderson, GA ;
Udseth, HR ;
Conrads, TP ;
Veenstra, TD ;
Masselon, CD ;
Gorshkov, MV ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :253-261
[10]   Electron capture dissociation of multiply-charged oxygenated cations. A nonergodic process [J].
Cerda, BA ;
Horn, DM ;
Breuker, K ;
Carpenter, BK ;
McLafferty, FW .
EUROPEAN MASS SPECTROMETRY, 1999, 5 (05) :335-338