External validation of exhaled breath profiling using an electronic nose in the discrimination of asthma with fixed airways obstruction and chronic obstructive pulmonary disease

被引:123
作者
Fens, N. [1 ]
Roldaan, A. C. [2 ]
van der Schee, M. P. [1 ]
Boksem, R. J. [1 ]
Zwinderman, A. H. [3 ]
Bel, E. H. [1 ]
Sterk, P. J. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Resp Med, NL-1100 DE Amsterdam, Netherlands
[2] Haga Teaching Hosp Leyweg, Dept Pulmonol, The Hague, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol & Biostat, NL-1100 DE Amsterdam, Netherlands
关键词
asthma; COPD; diagnostic accuracy; electronic nose; exhaled breath analysis; fixed airways obstruction; metabolomics; persistent airflow limitation; volatile organic compounds; VOLATILE ORGANIC-COMPOUNDS; AIR-FLOW OBSTRUCTION; GLOBAL STRATEGY; COPD; INFLAMMATION; ADULTS; STANDARDIZATION; IDENTIFICATION; SIMILARITIES; MECHANISMS;
D O I
10.1111/j.1365-2222.2011.03800.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background Fixed airflow limitation can be found both in asthma and chronic obstructive pulmonary disease (COPD), posing a day-to-day diagnostic challenge. Objective We aimed to determine the external validity of metabolomic analysis of exhaled air by electronic nose for distinguishing asthma and COPD in patients with fixed airways obstruction. Methods One hundred patients were included in a cross-sectional design: 60 asthma patients: 21 with fixed airways obstruction (fixed asthma), 39 with reversible airways obstruction (classic asthma) and 40 COPD patients (GOLD stages II-III). Standardized sampling of exhaled breath was performed and volatile organic compounds were captured using an electronic nose resulting in breathprints. External validity in newly recruited patients (validation sets) was tested using a previous and independent training set. Breathprints were analysed by principal component and canonical discriminant analysis and area under the curve (AUC) of receiver operating characteristic curves. Results External validity of breathprints showed 88% accuracy for distinguishing fixed asthma from COPD (AUC 0.95, 95% CI 0.84-1.00, sensitivity 85%, specificity 90%) and 83% for classic asthma (AUC 0.93, 95% CI 0.87-1.00, sensitivity 91%, specificity 90%) (both P<0.001). Discriminative accuracy was not confounded by current smoking. Conclusions and Clinical Relevance External validation of exhaled breath molecular profiling shows high accuracy in distinguishing asthma and COPD in newly recruited patients with fixed airways obstruction. Exhaled air analysis may therefore reduce misdiagnosis in obstructive airways diseases, potentially leading to more appropriate management.
引用
收藏
页码:1371 / 1378
页数:8
相关论文
共 39 条
[21]   The overlap syndrome of asthma and COPD: what are its features and how important is it? [J].
Gibson, P. G. ;
Simpson, J. L. .
THORAX, 2009, 64 (08) :728-735
[22]   Analysis of induced sputum in adults with asthma: identification of subgroup with isolated sputum neutrophilia and poor response to inhaled corticosteroids [J].
Green, RH ;
Brightling, CE ;
Woltmann, G ;
Parker, D ;
Wardlaw, AJ ;
Pavord, ID .
THORAX, 2002, 57 (10) :875-879
[23]   Exhaled biomarkers [J].
Kharitonov, Sergei A. ;
Barnes, Peter J. .
CHEST, 2006, 130 (05) :1541-1546
[24]   Assessment of the accuracy of diagnostic tests: the cross-sectional study [J].
Knottnerus, JA ;
Muris, JW .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2003, 56 (11) :1118-1128
[25]   Electronic Nose Breathprints Are Independent of Acute Changes in Airway Caliber in Asthma [J].
Lazar, Zsofia ;
Fens, Niki ;
van der Maten, Jan ;
van der Schee, Marc P. ;
Wagener, Ariane H. ;
de Nijs, Selma B. ;
Dijkers, Erica ;
Sterk, Peter J. .
SENSORS, 2010, 10 (10) :9127-9138
[26]   Comparisons between mammalian and artificial olfaction based on arrays of carbon black-polymer composite vapor detectors [J].
Lewis, NS .
ACCOUNTS OF CHEMICAL RESEARCH, 2004, 37 (09) :663-672
[27]   Standardisation of the single-breath determination of carbon monoxide uptake in the lung [J].
MacIntyre, N ;
Crapo, RO ;
Viegi, G ;
Johnson, DC ;
van der Grinten, CPM ;
Brusasco, V ;
Burgos, F ;
Casaburi, R ;
Coates, A ;
Enright, P ;
Gustafsson, P ;
Hankinson, J ;
Jensen, R ;
McKay, R ;
Miller, MR ;
Navajas, D ;
Pedersen, OF ;
Pellegrino, R ;
Wanger, J .
EUROPEAN RESPIRATORY JOURNAL, 2005, 26 (04) :720-735
[28]   Pathologic similarities and differences between asthma and chronic obstructive pulmonary disease [J].
Mauad, Thais ;
Dolhnikoff, Marisa .
CURRENT OPINION IN PULMONARY MEDICINE, 2008, 14 (01) :31-38
[29]   Standardisation of spirometry [J].
Miller, MR ;
Hankinson, J ;
Brusasco, V ;
Burgos, F ;
Casaburi, R ;
Coates, A ;
Crapo, R ;
Enright, P ;
van der Grinten, CPM ;
Gustafsson, P ;
Jensen, R ;
Johnson, DC ;
MacIntyre, N ;
McKay, R ;
Navajas, D ;
Pedersen, OF ;
Pellegrino, R ;
Viegi, G ;
Wanger, J .
EUROPEAN RESPIRATORY JOURNAL, 2005, 26 (02) :319-338
[30]   Diagnostic Performance of an Electronic Nose, Fractional Exhaled Nitric Oxide, and Lung Function Testing in Asthma [J].
Montuschi, Paolo ;
Santonico, Marco ;
Mondino, Chiara ;
Pennazza, Giorgio ;
Mantini, Giulia ;
Martinelli, Eugenio ;
Capuano, Rosamaria ;
Ciabattoni, Giovanni ;
Paolesse, Roberto ;
Di Natale, Corrado ;
Barnes, Peter J. ;
D'Amico, Arnaldo .
CHEST, 2010, 137 (04) :790-796