Pulmonary gas-exchange analysis by using simultaneous deposition of aerosolized and injected microspheres

被引:46
作者
Altemeier, WA
Robertson, HT
Glenny, RW
机构
[1] Univ Washington, Dept Med, Seattle, WA 98195 USA
[2] Univ Washington, Dept Physiol & Biophys, Seattle, WA 98195 USA
关键词
ventilation heterogeneity; pulmonary blood flow; ventilation-perfusion matching; aerosol; fluorescent microspheres;
D O I
10.1152/jappl.1998.85.6.2344
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Numerical methods for determining end-capillary gas contents for ventilation-to-perfusion ratios were first developed in the late 1960s. In the 1970s these methods were applied to validate distributions of ventilation-to-perfusion ratios measured by the multiple inert-gas-elimination technique. We combined numerical gas analysis and fluorescent-microsphere measurements of ventilation and perfusion to predict gas exchange at a resolution of similar to 2.0-cm(3) lung volume in pigs. Oxygen, carbon dioxide, and inert gas exchange were calculated in 551-845 compartments/animal before and after pulmonary embolization with 780-mu m beads. Whole lung gas exchange was estimated from the perfusion- and ventilation-weighted end-capillary gas contents. Before lung injury, no significant difference existed between microsphere-estimated arterial PO2 and PCO2 and measured values. After lung injury, the microsphere method predicted a decrease in arterial PO2 but consistently underestimated its magnitude. Correlation between predicted and measured inert gas retentions was 0.99. Overestimation of low-solubility inert gas retentions suggests underestimation of areas with low ventilation-to-perfusion ratios by microspheres after lung injury. Regional deposition of aerosolized and injected microspheres is a valid method for investigating regional gas exchange with high spatial resolution.
引用
收藏
页码:2344 / 2351
页数:8
相关论文
共 28 条
[21]   SIMPLE, ACCURATE EQUATIONS FOR HUMAN-BLOOD O2 DISSOCIATION COMPUTATIONS [J].
SEVERINGHAUS, JW .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 46 (03) :599-602
[22]   TRACHEAL GAS-EXCHANGE - PERFUSION-RELATED DIFFERENCES IN INERT-GAS ELIMINATION [J].
SOUDERS, JE ;
GEORGE, SC ;
POLISSAR, NL ;
SWENSON, ER ;
HLASTALA, MP .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (03) :918-928
[23]   CONDUCTING AIRWAY GAS-EXCHANGE - DIFFUSION-RELATED DIFFERENCES IN INERT-GAS ELIMINATION [J].
SWENSON, ER ;
ROBERTSON, HT ;
POLISSAR, NL ;
MIDDAUGH, ME ;
HLASTALA, MP .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 72 (04) :1581-1588
[24]   MEASUREMENT OF CONTINUOUS DISTRIBUTIONS OF VENTILATION-PERFUSION RATIOS - THEORY [J].
WAGNER, PD ;
SALTZMAN, HA ;
WEST, JB .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 36 (05) :588-599
[25]  
WAGNER PD, 1977, BIOENGINEERING ASPEC, V3, P361
[26]   MODEST EFFECT OF TEMPERATURE ON THE PORCINE OXYGEN DISSOCIATION CURVE [J].
WILLFORD, DC ;
HILL, EP .
RESPIRATION PHYSIOLOGY, 1986, 64 (02) :113-123
[27]  
WILSON TA, 1992, J APPL PHYSIOL, V72, P229
[28]   DEAD SPACE AT REST AND DURING EXERCISE [J].
YOUNG, AC .