Pulmonary gas-exchange analysis by using simultaneous deposition of aerosolized and injected microspheres

被引:46
作者
Altemeier, WA
Robertson, HT
Glenny, RW
机构
[1] Univ Washington, Dept Med, Seattle, WA 98195 USA
[2] Univ Washington, Dept Physiol & Biophys, Seattle, WA 98195 USA
关键词
ventilation heterogeneity; pulmonary blood flow; ventilation-perfusion matching; aerosol; fluorescent microspheres;
D O I
10.1152/jappl.1998.85.6.2344
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Numerical methods for determining end-capillary gas contents for ventilation-to-perfusion ratios were first developed in the late 1960s. In the 1970s these methods were applied to validate distributions of ventilation-to-perfusion ratios measured by the multiple inert-gas-elimination technique. We combined numerical gas analysis and fluorescent-microsphere measurements of ventilation and perfusion to predict gas exchange at a resolution of similar to 2.0-cm(3) lung volume in pigs. Oxygen, carbon dioxide, and inert gas exchange were calculated in 551-845 compartments/animal before and after pulmonary embolization with 780-mu m beads. Whole lung gas exchange was estimated from the perfusion- and ventilation-weighted end-capillary gas contents. Before lung injury, no significant difference existed between microsphere-estimated arterial PO2 and PCO2 and measured values. After lung injury, the microsphere method predicted a decrease in arterial PO2 but consistently underestimated its magnitude. Correlation between predicted and measured inert gas retentions was 0.99. Overestimation of low-solubility inert gas retentions suggests underestimation of areas with low ventilation-to-perfusion ratios by microspheres after lung injury. Regional deposition of aerosolized and injected microspheres is a valid method for investigating regional gas exchange with high spatial resolution.
引用
收藏
页码:2344 / 2351
页数:8
相关论文
共 28 条
[1]   Pulmonary embolization causes hypoxemia by redistributing regional blood flow without changing ventilation [J].
Altemeier, WA ;
Robertson, HT ;
McKinney, S ;
Glenny, RW .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (06) :2337-2343
[2]  
ALTEMEIER WA, 1998, AM J RESP CRIT CARE, V157, pA370
[3]  
Anthonisen NR, 1987, HDB PHYSL 3, P113
[4]   GAS-EXCHANGE AFTER PULMONARY THROMBO-EMBOLIZATION IN DOGS [J].
DANTZKER, DR ;
WAGNER, PD ;
TORNABENE, VW ;
ALAZRAKI, NP ;
WEST, JB .
CIRCULATION RESEARCH, 1978, 42 (01) :92-103
[5]   A THEORETICAL STUDY OF THE COMPOSITION OF THE ALVEOLAR AIR AT ALTITUDE [J].
FENN, WO ;
RAHN, H ;
OTIS, AB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1946, 146 (05) :637-653
[6]   LUNG FUNCTION STUDIES .2. THE RESPIRATORY DEAD SPACE [J].
FOWLER, WS .
AMERICAN JOURNAL OF PHYSIOLOGY, 1948, 154 (03) :405-416
[7]   MODELING STEADY-STATE INERT-GAS EXCHANGE IN THE CANINE TRACHEA [J].
GEORGE, SC ;
SOUDERS, JE ;
BABB, AL ;
HLASTALA, MP .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (03) :929-940
[8]   FRACTAL PROPERTIES OF PULMONARY BLOOD-FLOW - CHARACTERIZATION OF SPATIAL HETEROGENEITY [J].
GLENNY, RW ;
ROBERTSON, HT .
JOURNAL OF APPLIED PHYSIOLOGY, 1990, 69 (02) :532-545
[9]   GRAVITY-INDEPENDENT INEQUALITY IN PULMONARY BLOOD-FLOW IN HUMANS [J].
HAKIM, TS ;
LISBONA, R ;
DEAN, GW .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (03) :1114-1121
[10]   HUMAN AIR SPACE SHAPES, SIZES, AREAS, AND VOLUMES [J].
HANSEN, JE ;
AMPAYA, EP .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 38 (06) :990-995