Quantitative perfusion measurements using pulsed arterial spin labeling: Effects of large region-of-interest analysis

被引:33
作者
Figueiredo, PM [1 ]
Clare, S [1 ]
Jezzard, P [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, Dept Clin Neurol, FMRIB Ctr, Oxford OX3 9DU, England
关键词
perfusion; ASL; quantitative analysis; transit time distribution; kinetic data;
D O I
10.1002/jmri.20329
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To study arterial spin labeling (ASL) MRI techniques and to investigate various problematic issues that still hinder the accurate and robust quantitative analysis of ASL data. Materials and Methods: A pulsed-ASL (PASL) sequence was implemented on a 3-T imaging system and a protocol was developed for the measurement of perfusion based on fitting to a standard kinetic model. Both numerical simulations and multi-inversion time MRI data were analyzed. The effect of fitting a kinetic curve to a large region of interest (ROI) with a distribution of arterial transit times was compared to a pixel-by-pixel (PBP) method. Results: It was found that a significant underestimation of perfusion of approximately 17 +/- 6% (P < 0.001) occurs in gray matter, when comparing an ROI with a PBP analysis over a group of 12 healthy subjects. Conclusion: Analysis of ASL data based on a large ROI may suffer from inaccuracies arising from a distribution of transit times, implying that averaging of ASL kinetic data over such regions should therefore be avoided. When possible, a PBP fit should be performed. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:676 / 682
页数:7
相关论文
共 9 条
[1]   A general kinetic model for quantitative perfusion imaging with arterial spin labeling [J].
Buxton, RB ;
Frank, LR ;
Wong, EC ;
Siewert, B ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :383-396
[2]   Measuring cerebral blood flow using magnetic resonance imaging techniques [J].
Calamante, F ;
Thomas, DL ;
Pell, GS ;
Wiersma, J ;
Turner, R .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1999, 19 (07) :701-735
[3]   Rapid T1 mapping using multislice echo planar imaging [J].
Clare, S ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :630-634
[4]   Arterial spin labeling in combination with a look-locker sampling strategy:: Inflow turbo-sampling EPI-FAIR (ITS-FAIR) [J].
Günther, M ;
Bock, M ;
Schad, LR .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (05) :974-984
[5]   Improved optimization for the robust and accurate linear registration and motion correction of brain images [J].
Jenkinson, M ;
Bannister, P ;
Brady, M ;
Smith, S .
NEUROIMAGE, 2002, 17 (02) :825-841
[6]   Normal cerebral perfusion measurements using arterial spin labeling: Reproducibility, stability, and age and gender effects [J].
Parkes, LM ;
Rashid, W ;
Chard, DT ;
Tofts, PS .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) :736-743
[7]  
Wong EC, 1997, NMR BIOMED, V10, P237, DOI 10.1002/(SICI)1099-1492(199706/08)10:4/5<237::AID-NBM475>3.0.CO
[8]  
2-X
[9]   Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithm [J].
Zhang, YY ;
Brady, M ;
Smith, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (01) :45-57