Angiographic imaging with 2D RF pulses

被引:48
作者
Alley, MT [1 ]
Pauly, JM [1 ]
Sommer, FG [1 ]
Pelc, NJ [1 ]
机构
[1] STANFORD UNIV, DEPT ELECT ENGN, STANFORD, CA 94305 USA
关键词
RF pulse design; multi-dimensional selective excitation; magnetic resonance angiography; small field-of-view imaging;
D O I
10.1002/mrm.1910370220
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance angiography (MRA) was performed by using RF pulses designed to excite a limited spatial extent in two orthogonal directions. The restriction in the second spatial dimension can be used to increase inflow enhancement and to improve small field-of-view imaging. A rectangular excitation was produced with an ''echo-planar'' k-space trajectory and a sine-modulated RF waveform. In vivo images have demonstrated that vessels are more clearly delineated with the two-dimensional excitation. Aliasing artifacts in smalt field-of-view imaging are significantly reduced, although in some cases complete elimination is not possible due to the nature of the gradient trajectory.
引用
收藏
页码:260 / 267
页数:8
相关论文
共 15 条
[1]   TWO-DIMENSIONAL SPATIALLY SELECTIVE SPIN INVERSION AND SPIN-ECHO REFOCUSING WITH A SINGLE NUCLEAR-MAGNETIC-RESONANCE PULSE [J].
BOTTOMLEY, PA ;
HARDY, CJ .
JOURNAL OF APPLIED PHYSICS, 1987, 62 (10) :4284-4290
[2]   ANALYSIS OF FLOW EFFECTS IN ECHO-PLANAR IMAGING [J].
BUTTS, K ;
RIEDERER, SJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :285-293
[3]   PHASE-VELOCITY MAPPING WITH A REAL-TIME LINE SCAN TECHNIQUE [J].
BUTTS, K ;
HANGIANDREOU, NJ ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) :134-138
[4]   IMAGING OF THE RENAL-ARTERIES - VALUE OF MR ANGIOGRAPHY [J].
DEBATIN, JF ;
SPRITZER, CE ;
GRIST, TM ;
BEAM, C ;
SVETKEY, LP ;
NEWMAN, GE ;
SOSTMAN, HD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (05) :981-990
[5]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[6]   INNER VOLUME MR IMAGING - TECHNICAL CONCEPTS AND THEIR APPLICATION [J].
FEINBERG, DA ;
HOENNINGER, JC ;
CROOKS, LE ;
KAUFMAN, L ;
WATTS, JC ;
ARAKAWA, M .
RADIOLOGY, 1985, 156 (03) :743-747
[7]   MR VASCULAR IMAGING WITH A FAST GRADIENT REFOCUSING PULSE SEQUENCE AND REFORMATTED IMAGES FROM TRANSAXIAL SECTIONS [J].
GULLBERG, GT ;
WEHRLI, FW ;
SHIMAKAWA, A ;
SIMONS, MA .
RADIOLOGY, 1987, 165 (01) :241-246
[8]   A MONITORING, FEEDBACK, AND TRIGGERING SYSTEM FOR REPRODUCIBLE BREATH-HOLD MR-IMAGING [J].
LIU, YL ;
RIEDERER, SJ ;
ROSSMAN, PJ ;
GRIMM, RC ;
DEBBINS, JP ;
EHMAN, RL .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (04) :507-511
[9]  
MORAN P R, 1982, Magnetic Resonance Imaging, V1, P197
[10]   MAGNETIC-RESONANCE ANGIOGRAPHY [J].
NISHIMURA, DG ;
MACOVSKI, A ;
PAULY, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (03) :140-151