Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults

被引:154
作者
Jensen, LA [1 ]
Onyskiw, JE [1 ]
Prasad, NGN [1 ]
机构
[1] Univ Alberta, Fac Nursing, Edmonton, AB T6G 2G3, Canada
来源
HEART & LUNG | 1998年 / 27卷 / 06期
关键词
D O I
10.1016/S0147-9563(98)90086-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: The purposes of the study were to: (1) describe the aggregate strength of the relationship of arterial oxygen saturation as measured by pulse oximetry with the standard of arterial blood,aas analysis as measured by co-oximetry, (2) examine how various factors affect this relationship, and (3) describe an aggregate estimate of the bias and precision between oxygen saturation as measured by pulse oximetry and the standard in vitro measures. DESIGN: A meta-analysis was conducted. SAMPLE: Seventy-four studies from 1976 to 1994 met the inclusion criteria of: (1) adult study population, (2) quantitative analysis of empirical data, and (3) bivariate correlations or bias and precision estimates between pulse oximeter and co-oximeter values. RESULTS: There were a total of 169 oximeter trials on 41 oximeter models from 25 different manufacturers. Studies were conducted in various settings with a variety of subjects, with most being healthy adult volunteers. The weighted mean r, based on 39 studies (62 oximeter trials) for which the r statistic and number of data points were available, was 0.895 (var [r] = 0.014). Based on 23 studies (82 oximeter trials) for which bias and precision estimates and number of data points were available, the mean absolute bias and precision were 1.999 and 0.233, respectively. Several factors were found to affect the accuracy of pulse oximetry. CONCLUSION: Pulse oximeters were found to be accurate within 2% (+/- 1 SD) or 5% (+/- 2 SD) of in vitro oximetry in the range of 70% to 100% Sao(2). In comparing ear and finger probes, readings from finger probes were more accurate. Pulse oximeters may fail to record accurately the true Sao(2) during severe or rapid desaturation, hypotension, hypothermia, dyshemoglobinemia, and low perfusion slates.
引用
收藏
页码:387 / 408
页数:22
相关论文
共 212 条
[21]  
CHAUDHARY BA, 1978, AM REV RESPIR DIS, V117, P173
[22]  
CHELLURI L, 1991, Respiratory Care, V36, P1383
[23]   COMPARISON OF RECORDED VALUES FROM 6 PULSE OXIMETERS [J].
CHOE, H ;
TASHIRO, C ;
FUKUMITSU, K ;
YAGI, M ;
YOSHIYA, I .
CRITICAL CARE MEDICINE, 1989, 17 (07) :678-681
[24]   A COMPARISON OF THE PERFORMANCE OF 20 PULSE OXIMETERS UNDER CONDITIONS OF POOR PERFUSION [J].
CLAYTON, DG ;
WEBB, RK ;
RALSTON, AC ;
DUTHIE, D ;
RUNCIMAN, WB .
ANAESTHESIA, 1991, 46 (01) :3-10
[25]   PULSE OXIMETER PROBES - A COMPARISON BETWEEN FINGER, NOSE, EAR AND FOREHEAD PROBES UNDER CONDITIONS OF POOR PERFUSION [J].
CLAYTON, DG ;
WEBB, RK ;
RALSTON, AC ;
DUTHIE, D ;
RUNCIMAN, WB .
ANAESTHESIA, 1991, 46 (04) :260-265
[26]  
COTE CJ, 1988, ANESTH ANALG, V67, P683
[27]   AMBULATORY MONITORING OF ARTERIAL OXYGEN-SATURATION [J].
DECKER, MJ ;
HOEKJE, PL ;
STROHL, KP .
CHEST, 1989, 95 (04) :717-722
[28]   INVITRO INVESTIGATION OF THE FACTORS AFFECTING PULSE OXIMETRY [J].
DEKOCK, JP ;
TARASSENKO, L .
JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (01) :61-66
[29]  
Desiderio D P, 1990, J Cardiothorac Anesth, V4, P30, DOI 10.1016/0888-6296(90)90443-J
[30]   PULSE OXIMETRY MONITORING CAN CHANGE ROUTINE OXYGEN SUPPLEMENTATION PRACTICES IN THE POSTANESTHESIA CARE UNIT [J].
DIBENEDETTO, RJ ;
GRAVES, SA ;
GRAVENSTEIN, N ;
KONICEK, C .
ANESTHESIA AND ANALGESIA, 1994, 78 (02) :365-368