High-resolution black-blood MRI of the carotid vessel wall using phased-array coils at 1.5 and 3 Tesla

被引:21
作者
Anumula, S [1 ]
Song, HK [1 ]
Wright, AC [1 ]
Wehrli, FW [1 ]
机构
[1] Univ Penn Hlth Syst, Dept Radiol, Lab Struct NMR Imaging, Philadelphia, PA 19104 USA
关键词
high-field MRI; 3; Tesla; carotid arteries; phased-array coils; SNR;
D O I
10.1016/j.acra.2005.08.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The aim of this report is to investigate the magnetic field dependence of the signal-to-noise ratio (SNR) for carotid vessel wall magnetic resonance imaging using phased-array (PA) surface coils by comparing images obtained at 1.5 and 3 Tesla (T) and determine the extent to which the improved SNR at the higher field can be traded for improved spatial resolution. Materials and Methods. Two pairs of dual-element PA coils were constructed for operation at the two field strengths. The individual elements of each PA were matched to 50 Omega impedance on the neck and tuned at the respective frequencies. The coils were evaluated on a cylindrical phantom positioned with its axis parallel to the main field and the coils placed on either side of the phantom parallel to the sagittal plane. In vivo magnetic resonance images of the carotid arteries were obtained in five subjects at both field strengths with a fast spin-echo double-inversion black-blood pulse sequence with fat saturation. SNR was measured at both field strengths by using standard techniques. Results. At a depth corresponding to the average location of the carotid arteries in the study subjects, mean phantom SNR for the two coils was higher at 3 T by a factor of 2.5. The greater than linear increase is caused by only partial coil loading of these relatively small coils. The practically achievable average SNR gain in vivo was 2.1. The lower in vivo SNR gain is attributed to a reduction in T-2 and prolongation of T-1 at the higher field strength and, to a lesser extent, the requirement for a decreased refocusing pulse flip angle to operate within specific absorption rate limits. The superior SNR at 3 T appears to provide considerably improved vessel-wall delineation. Conclusions. Carotid artery vessel-wall magnetic resonance imaging using PA surface coils provides a considerable increase in SNR when field strength is increased from 1.5 to 3 T. This increase can be traded for enhanced in-plane resolution.
引用
收藏
页码:1521 / 1526
页数:6
相关论文
共 22 条
[1]   The sensitivity of low flip angle RARE imaging [J].
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :176-184
[2]   RF MAGNETIC-FIELD PENETRATION, PHASE-SHIFT AND POWER DISSIPATION IN BIOLOGICAL TISSUE - IMPLICATIONS FOR NMR IMAGING [J].
BOTTOMLEY, PA ;
ANDREW, ER .
PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (04) :630-643
[3]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[4]  
BUSSE RF, 2003, P INT SOC MAG RESON, V11, P206
[5]   VARIABLE-RATE SELECTIVE EXCITATION [J].
CONOLLY, S ;
NISHIMURA, D ;
MACOVSKI, A ;
GLOVER, G .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :440-458
[6]   FAST SELECTIVE BLACK BLOOD MR IMAGING [J].
EDELMAN, RR ;
CHIEN, D ;
KIM, D .
RADIOLOGY, 1991, 181 (03) :655-660
[7]   THE INTRINSIC SIGNAL-TO-NOISE RATIO IN NMR IMAGING [J].
EDELSTEIN, WA ;
GLOVER, GH ;
HARDY, CJ ;
REDINGTON, RW .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) :604-618
[8]  
Fayad ZA, 2000, CIRCULATION, V102, P506
[9]   NUCLEAR-RELAXATION OF HUMAN BRAIN GRAY AND WHITE MATTER - ANALYSIS OF FIELD-DEPENDENCE AND IMPLICATIONS FOR MRI [J].
FISCHER, HW ;
RINCK, PA ;
VANHAVERBEKE, Y ;
MULLER, RN .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :317-334
[10]   Surface coil phased arrays for high-resolution imaging of the carotid arteries [J].
Hayes, CE ;
Mathis, CM ;
Yuan, C .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01) :109-112