Surface coil phased arrays for high-resolution imaging of the carotid arteries

被引:103
作者
Hayes, CE
Mathis, CM
Yuan, C
机构
[1] Department of Radiology, Diagnostic Imaging Sciences Center, University of Washington, Seattle, WA 98195
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1996年 / 6卷 / 01期
关键词
MR phased array; carotid bifurcation; MR imaging;
D O I
10.1002/jmri.1880060121
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An MR phased-array coil assembly was developed to obtain high-resolution images of atherosclerotic plaques in the carotid artery, images of volunteers and patients obtained by using alternative coil designs provided a subjective assessment of the coils' performance, field of view, ease of use, and susceptibility to motion artifacts, A quantitative measurement performed on a phantom indicated that a two-coil phased-array design should produce a 37% better signal-to-noise ratio at the carotids than would a conventional single 3-inch surface coil.
引用
收藏
页码:109 / 112
页数:4
相关论文
共 10 条
[1]   CHARACTERIZATION OF ATHEROSCLEROSIS WITH A 1.5-T IMAGING-SYSTEM [J].
GOLD, GE ;
PAULY, JM ;
GLOVER, GH ;
MORETTO, JC ;
MACOVSKI, A ;
HERFKENS, RJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (02) :399-407
[2]   VOLUME IMAGING WITH MR PHASED-ARRAYS [J].
HAYES, CE ;
HATTES, N ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :309-319
[3]   NOISE CORRELATIONS IN DATA SIMULTANEOUSLY ACQUIRED FROM MULTIPLE SURFACE COIL ARRAYS [J].
HAYES, CE ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :181-191
[4]   IMAGE-ANALYSIS AND QUANTIFICATION OF ATHEROSCLEROSIS USING MRI [J].
MERICKEL, MB ;
CARMAN, CS ;
BROOKEMAN, JR ;
AYERS, CR .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1991, 15 (04) :207-216
[5]   MRI STUDIES OF ATHEROSCLEROTIC VASCULAR-DISEASE - STRUCTURAL EVALUATION AND PHYSIOLOGICAL MEASUREMENTS [J].
MOHIADDIN, RH ;
LONGMORE, DB .
BRITISH MEDICAL BULLETIN, 1989, 45 (04) :968-990
[6]   NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY OF ATHEROMA IN HUMAN CORONARY-ARTERIES [J].
PEARLMAN, JD ;
SOUTHERN, JF ;
ACKERMAN, JL .
ANGIOLOGY, 1991, 42 (09) :726-733
[7]   THE NMR PHASED-ARRAY [J].
ROEMER, PB ;
EDELSTEIN, WA ;
HAYES, CE ;
SOUZA, SP ;
MUELLER, OM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :192-225
[8]   TECHNIQUES FOR HIGH-RESOLUTION MR-IMAGING OF ATHEROSCLEROTIC PLAQUE [J].
YUAN, C ;
TSURUDA, JS ;
BEACH, KN ;
HAYES, CE ;
FERGUSON, MS ;
ALPERS, CE ;
FOO, TK ;
STRANDNESS, DE .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (01) :43-49
[9]   PHASED-ARRAY MAGNETIC-RESONANCE-IMAGING OF THE CAROTID-ARTERY BIFURCATION - PRELIMINARY-RESULTS IN HEALTHY-VOLUNTEERS AND A PATIENT WITH ATHEROSCLEROTIC DISEASE [J].
YUAN, C ;
MURAKAMI, JW ;
HAYES, CE ;
TSURUDA, JS ;
HATSUKAMI, TS ;
WILDY, KS ;
FERGUSON, MS ;
STRANDNESS, DE .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (05) :561-565
[10]  
1991, STROKE, V22, P711