In vivo video rate optical coherence tomography

被引:386
作者
Rollins, AM [1 ]
Kulkarni, MD
Yazdanfar, S
Ung-arunyawee, R
Izatt, JA
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Med, Cleveland, OH 44106 USA
关键词
D O I
10.1364/OE.3.000219
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An optical coherence tomography system is described which can image up to video rate. The system utilizes a high power broadband source and real time image acquisition hardware and features a high speed scanning delay line in the reference arm based on Fourier-transform pulse shaping technology. The theory of low coherence interferometry with a dispersive delay line, and the operation of the delay line are detailed and the design equations of the system are presented. Real time imaging is demonstrated in vivo in tissues relevant to early human disease diagnosis (skin, eye) and in an important model in developmental biology (Xenopus laevis). (C)1998 Optical Society of America
引用
收藏
页码:219 / 229
页数:11
相关论文
共 28 条
[11]   Image enhancement in optical coherence tomography using deconvolution [J].
Kulkarni, MD ;
Thomas, CW ;
Izatt, JA .
ELECTRONICS LETTERS, 1997, 33 (16) :1365-1367
[12]   400-HZ MECHANICAL SCANNING OPTICAL DELAY-LINE [J].
KWONG, KF ;
YANKELEVICH, D ;
CHU, KC ;
HERITAGE, JP ;
DIENES, A .
OPTICS LETTERS, 1993, 18 (07) :558-560
[14]   NOISE CHARACTERISTICS OF HIGH-POWER DOPED-FIBER SUPERLUMINESCENT SOURCES [J].
MORKEL, PR ;
LAMING, RI ;
PAYNE, DN .
ELECTRONICS LETTERS, 1990, 26 (02) :96-98
[15]   TRANSVERSAL AND LONGITUDINAL IMAGES FROM THE RETINA OF THE LIVING EYE USING LOW COHERENCE REFLECTOMETRY [J].
Podoleanu, Adrian Gh. ;
Seeger, Mauritius ;
Dobre, George M. ;
Webb, David J. ;
Jackson, David A. ;
Fitzke, Fred W. .
JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (01) :12-20
[16]   CW AUTO-CORRELATION MEASUREMENTS OF PICOSECOND LASER-PULSES [J].
SALA, KL ;
KENNEYWALLACE, GA ;
HALL, GE .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1980, 16 (09) :990-996
[17]   In vivo endoscopic OCT imaging of precancer and cancer states of human mucosa [J].
Sergeev, A. M. ;
Gelikonov, V. M. ;
Gelikonov, G. V. ;
Feldchtein, F. I. ;
Kuranov, R. V. ;
Gladkova, N. D. ;
Shakhova, N. M. ;
Snopova, L. B. ;
Shakhov, A. V. ;
Kuznetzova, I. A. ;
Denisenko, A. N. ;
Pochinko, V. V. ;
Chumakov, Yu. P. ;
Streltzova, O. S. .
OPTICS EXPRESS, 1997, 1 (13) :432-440
[18]   Achieving variation of the optical path length by a few millimeters at millisecond rates for imaging of turbid media and optical interferometry: A new technique [J].
Su, CB .
OPTICS LETTERS, 1997, 22 (10) :665-667
[19]   HIGH-SPEED OPTICAL COHERENCE DOMAIN REFLECTOMETRY [J].
SWANSON, EA ;
HUANG, D ;
HEE, MR ;
FUJIMOTO, JG ;
LIN, CP ;
PULIAFITO, CA .
OPTICS LETTERS, 1992, 17 (02) :151-153
[20]   Rapid acquisition of in vivo biological images by use of optical coherence tomography [J].
Tearney, GJ ;
Bouma, BE ;
Boppart, SA ;
Golubovic, B ;
Swanson, EA ;
Fujimoto, JG .
OPTICS LETTERS, 1996, 21 (17) :1408-1410