Real-Time Diffusion-Perfusion Mismatch Analysis in Acute Stroke

被引:345
作者
Straka, Matus [2 ]
Albers, Gregory W. [2 ,3 ]
Bammer, Roland [1 ]
机构
[1] Stanford Univ, Dept Radiol, Lucas Ctr, Stanford, CA 94305 USA
[2] Stanford Univ, Med Center, Stanford Stroke Ctr, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Neurol & Neurol Sci, Stanford, CA 94305 USA
关键词
perfusion; diffusion; mismatch; acute stroke; automated data processing; CEREBRAL-BLOOD-FLOW; SUSCEPTIBILITY CONTRAST MRI; ARTERIAL INPUT FUNCTION; SINGULAR-VALUE DECOMPOSITION; COMPUTED-TOMOGRAPHY; THEORETICAL BASIS; ENHANCED MR; QUANTIFICATION; VOLUME; TISSUE;
D O I
10.1002/jmri.22338
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diffusion-perfusion mismatch can be used to identify acute stroke patients that could benefit from reperfusion therapies. Early assessment of the mismatch facilitates necessary diagnosis and treatment decisions in acute stroke. We developed the RApid processing of Perfusion and Diffusion (RAPID) for unsupervised, fully automated processing of perfusion and diffusion data for the purpose of expedited routine clinical assessment. The RAPID system computes quantitative perfusion maps (cerebral blood volume, CBV; cerebral blood flow, CBF; mean transit time, MTT; and the time until the residue function reaches its peak, T-max) using deconvolution of tissue and arterial signals. Diffusion-weighted imaging/perfusion-weighted imaging (DWI/PWI) mismatch is automatically determined using infarct core segmentation of ADC maps and perfusion deficits segmented from T-max maps. The performance of RAPID was evaluated on 63 acute stroke cases, in which diffusion and perfusion lesion volumes were outlined by both a human reader and the RAPID system. The correlation of outlined lesion volumes obtained from both methods was r(2) = 0.99 for DWI and r(2) = 0.96 for PWI. For mismatch identification, RAPID showed 100% sensitivity and 91% specificity. The mismatch information is made available on the hospital's PACS within 5-7 mm. Results indicate that the automated system is sufficiently accurate and fast enough to be used for routine care as well as in clinical trials.
引用
收藏
页码:1024 / 1037
页数:14
相关论文
共 50 条
[1]   Magnetic resonance imaging profiles predict clinical response to early reperfusion: The diffusion and perfusion imaging evaluation for understanding stroke evolution (DEFUSE) study [J].
Albers, Gregory W. ;
Thijs, Vincent N. ;
Wechsle, Lawrence ;
Kemp, Stephanie ;
Schlaug, Gottfried ;
Skalabrin, Elaine ;
Bammer, Roland ;
Kakuda, Wataru ;
Lansberg, Maarten G. ;
Shuaib, Ashfaq ;
Coplin, William ;
Hamilton, Scott ;
Moseley, Michael ;
Marks, Michael P. .
ANNALS OF NEUROLOGY, 2006, 60 (05) :508-517
[2]  
ALSOP D, 2001, P 9 ANN M ISMRM GLAS
[3]  
*ASIST JAP, 2009, PERF MISM AN VERS 3
[5]   Diffusion-weighted imaging with navigated interleaved echo-planar imaging and a conventional gradient system [J].
Bammer, P ;
Stollberger, R ;
Augustin, M ;
Simbrunner, J ;
Offenbacher, H ;
Kooijman, H ;
Ropele, S ;
Kapeller, P ;
Wach, P ;
Ebner, F ;
Fazekas, F .
RADIOLOGY, 1999, 211 (03) :799-806
[6]  
Boxerman JL, 2006, AM J NEURORADIOL, V27, P859
[7]   Quantification of bolus-tracking MRI: Improved characterization of the tissue residue function using Tikhonov regularization [J].
Calamante, F ;
Gadian, DG ;
Connelly, A .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (06) :1237-1247
[8]  
Calamante F, 2000, MAGN RESON MED, V44, P466, DOI 10.1002/1522-2594(200009)44:3<466::AID-MRM18>3.0.CO
[9]  
2-M
[10]   Contrast agent concentration measurements affecting quantification of bolus-tracking perfusion MRI [J].
Calamante, Fernando ;
Vonken, Evert-jan P. A. ;
van Osch, Matthias J. P. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) :544-553