Particulate matter concentrations in residences: an intervention study evaluating stand-alone filters and air conditioners

被引:89
作者
Batterman, S. [1 ]
Du, L. [1 ,2 ]
Mentz, G. [1 ]
Mukherjee, B. [1 ]
Parker, E. [3 ]
Godwin, C. [1 ]
Chin, J. -Y. [1 ]
O'Toole, A. [1 ]
Robins, T. [1 ]
Rowe, Z. [4 ]
Lewis, T. [1 ,5 ]
机构
[1] Univ Michigan, Sch Publ Hlth, Ann Arbor, MI 48109 USA
[2] Donghua Univ, Sch Environm Sci & Engn, Shanghai, Peoples R China
[3] Univ Iowa, Coll Publ Hlth, Iowa City, IA USA
[4] Large, Community Act Asthma, Detroit, MI USA
[5] Univ Michigan, Sch Med, Ann Arbor, MI 48109 USA
关键词
Air filters; Air conditioner; Air exchange rate; Asthma; Intervention; Particulate matter; ENVIRONMENTAL INTERVENTION; PARTICLE CONCENTRATIONS; ASTHMATIC-CHILDREN; INDOOR; ALLERGENS; HOMES; RATES; EXPOSURES; BEDROOMS; OUTDOOR;
D O I
10.1111/j.1600-0668.2011.00761.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study, a randomized controlled trial, evaluated the effectiveness of free-standing air filters and window air conditioners (ACs) in 126 low-income households of children with asthma. Households were randomized into a control group, a group receiving a free-standing HEPA filter placed in the childs sleeping area, and a group receiving the filter and a window-mounted AC. Indoor air quality (IAQ) was monitored for week-long periods over three to four seasons. High concentrations of particulate matter (PM) and carbon dioxide were frequently seen. When IAQ was monitored, filters reduced PM levels in the childs bedroom by an average of 50%. Filter use varied greatly among households and declined over time, for example, during weeks when pollutants were monitored, filter use was initially high, averaging 84 +/- 27%, but dropped to 63 +/- 33% in subsequent seasons. In months when households were not visited, use averaged only 34 +/- 30%. Filter effectiveness did not vary in homes with central or room ACs. The study shows that measurements over multiple seasons are needed to characterize air quality and filter performance. The effectiveness of interventions using free-standing air filters depends on occupant behavior, and strategies to ensure filter use should be an integral part of interventions. Practical Implications Environmental tobacco smoke (ETS) increased particulate matter (PM) levels by about 14 mu g/m3 and was often detected using ETS-specific tracers despite restrictions on smoking in the house as reported on questionnaires administered to caregivers. PM concentrations depended on season, filter usage, relative humidity, air exchange ratios, number of children, outdoor PM levels, sweeping/dusting, and presence of a central air conditioner (AC). Free-standing air filters can be an effective intervention that provides substantial reductions in PM concentrations if the filters are used. However, filter use was variable across the study population and declined over the study duration, and thus strategies are needed to encourage and maintain use of filters. The variability in filter use suggests that exposure misclassification is a potential problem in intervention studies using filters. The installation of a room AC in the bedroom, intended to limit air exchange ratios, along with an air filter, did not lower PM levels more than the filter alone.
引用
收藏
页码:235 / 252
页数:18
相关论文
共 41 条
[11]   Home and allergic characteristics of children with asthma in seven US urban communities and design of an environmental intervention: The Inner-City Asthma Study [J].
Crain, EF ;
Walter, M ;
O'Connor, GT ;
Mitchell, H ;
Gruchalla, RS ;
Kattan, M ;
Malindzak, GS ;
Enright, P ;
Evans, R ;
Morgan, W ;
Stout, JW .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2002, 110 (09) :939-945
[12]  
Delfino RJ, 1997, ENVIRON HEALTH PERSP, V105, P622, DOI 10.2307/3433608
[13]   Particle concentrations and effectiveness of free-standing air filters in bedrooms of children with asthma in Detroit, Michigan [J].
Du, Liuliu ;
Batterman, Stuart ;
Parker, Edith ;
Godwin, Christopher ;
Chin, Jo-Yu ;
O'Toole, Ashley ;
Robins, Thomas ;
Brakefield-Caldwell, Wilma ;
Lewis, Toby .
BUILDING AND ENVIRONMENT, 2011, 46 (11) :2303-2313
[14]   Home environmental intervention in inner-city asthma: a randomized controlled clinical trial [J].
Eggleston, PA ;
Butz, A ;
Rand, C ;
Curtin-Brosnan, J ;
Kanchanaraksa, S ;
Swartz, L ;
Breysse, P ;
Buckley, T ;
Diette, G ;
Merriman, B ;
Krishnan, JA .
ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2005, 95 (06) :518-524
[15]   Predictors of Indoor Air Concentrations in Smoking and Non-Smoking Residences [J].
Heroux, Marie-Eve ;
Clark, Nina ;
Van Ryswyk, Keith ;
Mallick, Ranjeeta ;
Gilbert, Nicolas L. ;
Harrison, Ian ;
Rispler, Kathleen ;
Wang, Daniel ;
Anastassopoulos, Angelos ;
Guay, Mireille ;
MacNeill, Morgan ;
Wheeler, Amanda J. .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2010, 7 (08) :3080-3099
[16]   Emission rates due to indoor activities:: Indoor aerosol model development, evaluation, and applications [J].
Hussein, T ;
Korhonen, H ;
Herrmann, E ;
Hämeri, KH ;
Lehtinen, KEJ ;
Kulmala, M .
AEROSOL SCIENCE AND TECHNOLOGY, 2005, 39 (11) :1111-1127
[17]   Continuous, intermittent and passive sampling of airborne VOCs [J].
Jia, Chunrong ;
Batterman, Stuart ;
Godwin, Christopher .
JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (11) :1220-1230
[18]   Assessment of personal and community-level exposures to particulate matter among children with asthma in Detroit, Michigan, as part of Community Action Against Asthma (CAAA) [J].
Keeler, GJ ;
Dvonch, JT ;
Yip, FY ;
Parker, EA ;
Israel, BA ;
Marsik, FJ ;
Morishita, M ;
Barres, JA ;
Robins, TG ;
Brakefield-Caldwell, W ;
Sam, M .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2002, 110 :173-181
[19]   The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutants [J].
Klepeis, NE ;
Nelson, WC ;
Ott, WR ;
Robinson, JP ;
Tsang, AM ;
Switzer, P ;
Behar, JV ;
Hern, SC ;
Engelmann, WH .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2001, 11 (03) :231-252
[20]   Determinants of indoor air concentrations of PM2.5, black smoke and NO2 in six European cities (EXPOLIS study) [J].
Lai, HK ;
Bayer-Oglesby, L ;
Colvile, R ;
Götschi, T ;
Jantunen, MJ ;
Künzli, N ;
Kulinskaya, E ;
Schweizer, C ;
Nieuwenhuijsen, MJ .
ATMOSPHERIC ENVIRONMENT, 2006, 40 (07) :1299-1313