Robustness of late lumen loss in discriminating drug-eluting stents across variable observational and randomized trials

被引:128
作者
Mauri, L
Orav, EJ
Candia, SC
Cutlip, DE
Kuntz, RE
机构
[1] Brigham & Womens Hosp, Boston, MA 02116 USA
[2] Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[3] Harvard Univ, Clin Res Inst, Boston, MA 02115 USA
[4] Harvard Univ, Sch Med, Boston, MA 02115 USA
关键词
angioplasty; coronary disease; restenosis; stents; trials;
D O I
10.1161/CIRCULATIONAHA105.570093
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Binary angiographic and clinical restenosis rates can vary widely between clinical studies, even for the same stent, influenced heavily by case-mix covariates that differ among observational and randomized trials intended to assess a given stent system. We hypothesized that mean in-stent late loss might be a more stable estimator of restenosis propensity across such studies. Methods and Result: In 46 trials of drug-eluting and bare-metal stenting, increasing mean late loss was associated with higher target lesion revascularization (TLR) rates (P < 0.001). When the class of bare-metal stents was compared with the class of effective drug-eluting stents, late loss was more discriminating than TLR as measured by the high intraclass correlation coefficient (rho) (late loss, rho = 0.71 versus TLR, rho = 0.22; 95% CI of difference = 0.33, 0.65). When the individual drug-eluting stents and bare-metal stents were compared, late loss was a better discriminator than TLR (0.68 versus 0.19; 95% CI of difference = 0.24, 0.60). Greater adjustments of study covariates are needed to stabilize assessments of TLR compared with late loss because of greater influence of reference vessel diameter on TLR than on in-stent late loss. Optimization of late loss with the use of a novel method of standardization according to diabetes prevalence and mean lesion length resulted in minor adjustments in late loss (< 0.08 mm for 90% of reported trials) and an ordered array of mean late loss values for the stent systems studied. Conclusions: Late loss is more reliable than restenosis rates for discriminating restenosis propensity between new drug-eluting stent platforms across studies and might be the optimum end point for evaluating drug-eluting stents in early, nonrandomized studies.
引用
收藏
页码:2833 / 2839
页数:7
相关论文
共 56 条
[51]   A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease [J].
Stone, GW ;
Ellis, SG ;
Cox, DA ;
Hermiller, J ;
O'Shaughnessy, C ;
Mann, JT ;
Turco, M ;
Caputo, R ;
Bergin, P ;
Greenberg, J ;
Popma, JJ ;
Russell, ME .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (03) :221-231
[52]  
STONE GW, 2005, AM COLL CARD MARCH 6
[53]   Effects of gold coating of coronary stents on neointimal proliferation following stent implantation [J].
vom Dahl, J ;
Haager, PK ;
Grube, E ;
Gross, M ;
Beythien, C ;
Kromer, EP ;
Cattelaens, N ;
Hamm, CW ;
Hoffmann, R ;
Reineke, T ;
Klues, HG .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (07) :801-805
[54]  
WIJNS W, 2005, AM COLL CARD MARCH 6
[55]   Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization [J].
Windecker, S ;
Remondino, A ;
Eberli, FR ;
Jüni, P ;
Räber, L ;
Wenaweser, P ;
Togni, M ;
Billinger, M ;
Tüller, D ;
Seiler, C ;
Roffi, M ;
Corti, R ;
Sütsch, G ;
Maier, W ;
Lüscher, T ;
Hess, OM ;
Egger, M ;
Meier, B .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (07) :653-662
[56]   Interventional cardiology - Does stent design affect probability of restenosis? A randomized trial comparing Multilink stents with GFX stents [J].
Yoshitomi, Y ;
Kojima, S ;
Yano, M ;
Sugi, T ;
Matsumoto, Y ;
Saotome, M ;
Tanaka, K ;
Endo, M ;
Kuramochi, M .
AMERICAN HEART JOURNAL, 2001, 142 (03) :445-451