Comparison of two stents in modifying cerebral aneurysm hemodynamics

被引:136
作者
Kim, Minsuok [1 ,2 ]
Taulbee, Dale B. [2 ]
Tremmel, Markus [1 ,3 ]
Meng, Hui [1 ,2 ,3 ]
机构
[1] SUNY Buffalo, Toshiba Stroke Res Ctr, Buffalo, NY 14214 USA
[2] SUNY Buffalo, Dept Mech & Aerosp Engn, Buffalo, NY 14260 USA
[3] SUNY Buffalo, Dept Neurosurg, Buffalo, NY 14209 USA
关键词
stent design; cerebral aneurysm; vessel geometry; anatomical aneurysm; hemodynamics; hydraulic resistance; Computational Fluid Dynamics; Tristar stent (TM); Wallstent (R);
D O I
10.1007/s10439-008-9449-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There is a general lack of quantitative understanding about how specific design features of endovascular stents (struts and mesh design, porosity) affect the hemodynamics in intracranial aneurysms. To shed light on this issue, we studied two commercial high-porosity stents (Tristar stent(TM) and Wallsten(R)) in aneurysm models of varying vessel curvature as well as in a patient-specific model using Computational Fluid Dynamics. We investigated how these stents modify hemodynamic parameters such as aneurysmal inflow rate, stasis, and wall shear stress, and how such changes are related to the specific designs. We found that the flow damping effect of stents and resulting aneurysmal stasis and wall shear stress are strongly influenced by stent porosity, strut design, and mesh hole shape. We also confirmed that the damping effect is significantly reduced at higher vessel curvatures, which indicates limited usefulness of high-porosity stents as a stand-alone treatment. Finally, we showed that the stasis-inducing performance of stents in 3D geometries can be predicted from the hydraulic resistance of their flat mesh screens. From this, we propose a methodology to cost-effectively compare different stent designs before running a full 3D simulation.
引用
收藏
页码:726 / 741
页数:16
相关论文
共 50 条
[41]  
PERKTOLD K, 1989, BIORHEOLOGY, V26, P1011
[42]   Measurement of flow modification in phantom aneurysm model: Comparison of coils and a longitudinally and axially asymmetric stent - Initial findings [J].
Rudin, S ;
Wang, Z ;
Kyprianou, I ;
Hoffmann, KR ;
Wu, Y ;
Meng, H ;
Guterman, LR ;
Nemes, B ;
Bednarek, DR ;
Dmochowski, J ;
Hopkins, LN .
RADIOLOGY, 2004, 231 (01) :272-276
[43]   Magnitude and role of wall shear stress on cerebral aneurysm - Computational fluid dynamic study of 20 middle cerebral artery aneurysms [J].
Shojima, M ;
Oshima, M ;
Takagi, K ;
Torii, R ;
Hayakawa, M ;
Katada, K ;
Morita, A ;
Kirino, T .
STROKE, 2004, 35 (11) :2500-2505
[44]   Image-based computational fluid dynamics modeling in realistic arterial geometries [J].
Steinman, DA .
ANNALS OF BIOMEDICAL ENGINEERING, 2002, 30 (04) :483-497
[45]   Finite-element modeling of the hemodynamics of stented aneurysms [J].
Stuhne, GR ;
Steinman, DA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (03) :382-387
[46]   Simulation of unsteady laminar flow in models of terminal aneurysm of the basilar artery [J].
Valencia, A .
INTERNATIONAL JOURNAL OF COMPUTATIONAL FLUID DYNAMICS, 2005, 19 (04) :337-345
[47]  
Vanninen R, 2003, AM J NEURORADIOL, V24, P263
[48]   Stents for intracranial aneurysms: The beginning of a new endovascular era? [J].
Wakhloo, AK ;
Lanzino, G ;
Lieber, BB ;
Hopkins, LN .
NEUROSURGERY, 1998, 43 (02) :377-379
[49]   A steady flow analysis on the stented and non-stented sidewall aneurysm models [J].
Yu, SCM ;
Zhao, JB .
MEDICAL ENGINEERING & PHYSICS, 1999, 21 (03) :133-141
[50]   CAROTID BIFURCATION ATHEROSCLEROSIS QUANTITATIVE CORRELATION OF PLAQUE LOCALIZATION WITH FLOW VELOCITY PROFILES AND WALL SHEAR-STRESS [J].
ZARINS, CK ;
GIDDENS, DP ;
BHARADVAJ, BK ;
SOTTIURAI, VS ;
MABON, RF ;
GLAGOV, S .
CIRCULATION RESEARCH, 1983, 53 (04) :502-514