Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis

被引:161
作者
Rizzo, S
Kalra, M
Schmidt, B
Dalal, T
Suess, C
Flohr, T
Blake, M
Saini, S
机构
[1] Emory Univ Hosp, Dept Radiol, Atlanta, GA 30322 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] Siemens Med Solut, Forchheim, Germany
关键词
abdomen; CT technique; pelvis; radiation dose; tube current modulation;
D O I
10.2214/AJR.04.1513
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to compare image quality and radiation dose associated with abdominopelvic CT using combined modulation, angular modulation, and constant tube current. CONCLUSION. Compared with using a constant tube current to scan the abdomen and pelvis, the use of a combined modulation technique results in a substantial reduction (42-44%) in radiation dose with acceptable image noise and diagnostic acceptability.
引用
收藏
页码:673 / 679
页数:7
相关论文
共 11 条
[1]  
*EUR, 16262 EUR
[2]   Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation [J].
Greess, H ;
Lutze, J ;
Nömayr, A ;
Wolf, H ;
Hothorn, T ;
Kalender, WA ;
Bautz, W .
EUROPEAN RADIOLOGY, 2004, 14 (06) :995-999
[3]   Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394
[4]  
Greess H, 1999, ROFO-FORTSCHR RONTG, V170, P246
[5]   Helical CT of the body: A survey of techniques used for pediatric patients [J].
Hollingsworth, C ;
Frush, DP ;
Cross, M ;
Lucaya, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) :401-406
[6]   Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers [J].
Kalender, WA ;
Wolf, H ;
Suess, C ;
Gies, M ;
Greess, H ;
Bautz, WA .
EUROPEAN RADIOLOGY, 1999, 9 (02) :323-328
[7]   Techniques and applications of automatic tube current modulation for CT [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Schmidt, B ;
Westerman, BL ;
Morgan, HT ;
Saini, S .
RADIOLOGY, 2004, 233 (03) :649-657
[8]   Sixteen-detector row CT of abdomen and pelvis: Study for optimization of Z-axis modulation technique performed in 153 patients [J].
Kalra, MK ;
Maher, MM ;
Kamath, RS ;
Horiuchi, T ;
Toth, TL ;
Halpern, EF ;
Saini, S .
RADIOLOGY, 2004, 233 (01) :241-249
[9]   Comparison of z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Kamath, RS ;
Halpern, EF ;
Saini, S .
RADIOLOGY, 2004, 232 (02) :347-353
[10]   Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628