Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers

被引:204
作者
Kalender, WA
Wolf, H
Suess, C
Gies, M
Greess, H
Bautz, WA
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Diagnost Radiol, D-8520 Erlangen, Germany
关键词
CT-dose; dose reduction; image quality;
D O I
10.1007/s003300050674
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We investigated approaches to reducing the dose in CT without impairing image quality. Dose can be reduced for non-circular object cross-sections without a significant increase in noise if X-ray tube current is reduced at angular tube positions where the X-ray attenuation by the patients is small. We investigated different schemes of current modulation during tube rotation by simulation and phantom measurements. Both pre-programmed sinusoidal modulation functions and attenuation-based on-line control of the tube current were evaluated. All relevant scan parameters were varied, including constraints such as the maximum modulation amplitude. A circular, an elliptical and two oval water phantoms were used. Results were validated on six cadavers. Dose reduction of 10-45% was obtained both in simulations and in measurements for the different non-circular phantom geometries and current modulation algorithms without an increase increase in pixel noise values. On-line attenuation-based control yielded higher reductions than modulation by a sinusoidal curve. The maximal dose reduction predicted by simulations could not be achieved due to limits in the modulation amplitude. In cadaver studies, a reduction of typically 20-40 % was achieved for the body and about 10% for the head. Variations of our technique are possible; a slight increase in normal tube current for high-attenuation projections combined with attenuation-based current modulation still yields significant dose reduction, but also a reduction in the structured noise that may obscure diagnostic details. We conclude that a significant reduction in dose can be achieved by tube current modulation without compromising image quality. Attenuation-based on-line control and a modulation amplitude of at least 90 % should be employed.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 6 条
[1]  
BAUER B, 1999, IN PRESS RAD PROTE S
[2]  
Giacomuzzi S M, 1996, Aktuelle Radiol, V6, P110
[3]  
GIES M, 1998, UNPUB MED PHYS
[4]  
GREESS H, 1998, ADV CT, V4, P35
[5]  
KALENDER WA, 1999, UNPUB MED PHYS
[6]   ANATOMICALLY ADAPTED VARIATION OF THE TUBE CURRENT IN CT - STUDIES ON REDUCTION OF RADIATION-DOSE AND IMAGE QUALITY [J].
KOPKA, L ;
FUNKE, M ;
BREITER, N ;
HERMANN, KP ;
VOSSHENRICH, R ;
GRABBE, E .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 163 (05) :383-387