Influence of imaging and histological factors on prostate cancer detection and localisation on multiparametric MRI: a prospective study

被引:259
作者
Bratan, Flavie [1 ,2 ]
Niaf, Emilie [2 ,9 ]
Melodelima, Christelle [3 ]
Chesnais, Anne Laure [4 ]
Souchon, Remi [2 ]
Mege-Lechevallier, Florence [4 ]
Colombel, Marc [5 ,6 ,7 ]
Rouviere, Olivier [1 ,2 ,5 ,6 ,8 ]
机构
[1] Hop Edouard Herriot, Dept Urinary & Vasc Radiol, F-69437 Lyon, France
[2] INSERM, LabTau, U1032, F-69003 Lyon, France
[3] Univ Grenoble 1, CNRS, UMR 5553, Lab Ecol Alpine, F-38041 Grenoble, France
[4] Hosp Civils Lyon, Hop Edouard Herriot, Dept Pathol, F-69437 Lyon, France
[5] Univ Lyon, F-69003 Lyon, France
[6] Univ Lyon 1, Fac Med Lyon Est, F-69003 Lyon, France
[7] Hosp Civils Lyon, Hop Edouard Herriot, Dept Urol, F-69437 Lyon, France
[8] Hop Edouard Herriot, Serv Radiol Urinaire & Vasc, F-69437 Lyon 03, France
[9] INSA Lyon, INSERM, U1044, CREATIS,CNRS,UMR5220, F-69100 Villeurbanne, France
关键词
Prostate cancer; Magnetic resonance imaging; Tumour localisation; Gleason score; Tumour volume; APPARENT DIFFUSION-COEFFICIENT; PELVIC PHASED-ARRAY; CONTRAST-ENHANCED MRI; 3; T; ENDORECTAL COIL; GLEASON SCORE; PROGNOSTIC-SIGNIFICANCE; FOCAL THERAPY; WEIGHTED MRI; TUMOR;
D O I
10.1007/s00330-013-2795-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess factors influencing prostate cancer detection on multiparametric (T2-weighted, diffusion-weighted, and dynamic contrast-enhanced) MRI. One hundred and seventy-five patients who underwent radical prostatectomy were included. Pre-operative MRI performed at 1.5 T (n = 71) or 3 T (n = 104), with (n = 58) or without (n = 117) an endorectal coil were independently interpreted by two radiologists. A five-point subjective suspicion score (SSS) was assigned to all focal abnormalities (FAs). MR findings were then compared with whole-mount sections. Readers identified 192-214/362 cancers, with 130-155 false positives. Detection rates for tumours of < 0.5 cc (cm(3)), 0.5-2 cc and > 2 cc were 33-45/155 (21-29 %), 15-19/35 (43-54 %) and 8-9/12 (67-75 %) for Gleason a parts per thousand currency sign6, 17/27 (63 %), 42-45/51 (82-88 %) and 34/35 (97 %) for Gleason 7 and 4/5 (80 %), 13/14 (93 %) and 28/28 (100 %) for Gleason a parts per thousand yen8 cancers respectively. At multivariate analysis, detection rates were influenced by tumour Gleason score, histological volume, histological architecture and location (P < 0.0001), but neither by field strength nor coils used for imaging. The SSS was a significant predictor of both malignancy of FAs (P < 0.005) and aggressiveness of tumours (P < 0.00001). Detection rates were significantly influenced by tumour characteristics, but neither by field strength nor coils used for imaging. The SSS significantly stratified the risk of malignancy of FAs and aggressiveness of detected tumours. aEuro cent Prostate cancer volume, Gleason score, architecture and location are MRI predictors of detection. aEuro cent Field strength and coils used do not influence the tumour detection rate. aEuro cent Multiparametric MRI is accurate for detecting aggressive tumours. aEuro cent A subjective suspicion score can stratify the risk of malignancy and tumour aggressiveness.
引用
收藏
页码:2019 / 2029
页数:11
相关论文
共 51 条
[21]   How good is MRI at detecting and characterising cancer within the prostate? [J].
Kirkham, Alexander P. S. ;
Emberton, Mark ;
Allen, Clare .
EUROPEAN UROLOGY, 2006, 50 (06) :1163-1175
[22]   Intermixed Normal Tissue within Prostate Cancer: Effect on MR Imaging Measurements of Apparent Diffusion Coefficient and T2-Sparse versus Dense Cancers [J].
Langer, Deanna L. ;
van der Kwast, Theodorus H. ;
Evans, Andrew J. ;
Sun, Laibao ;
Yaffe, Martin J. ;
Trachtenberg, John ;
Haider, Masoom A. .
RADIOLOGY, 2008, 249 (03) :900-908
[23]   Dynamic contrast-enhanced MRI of anterior prostate cancer: morphometric assessment and correlation with radical prostatectomy findings [J].
Lemaitre, Laurent ;
Puech, Philippe ;
Poncelet, Edouard ;
Bouye, Sebastien ;
Leroy, Xavier ;
Biserte, Jacques ;
Villers, Arnauld .
EUROPEAN RADIOLOGY, 2009, 19 (02) :470-480
[24]   Focal therapy in prostate cancer: modalities, findings and future considerations [J].
Lindner, Uri ;
Trachtenberg, John ;
Lawrentschuk, Nathan .
NATURE REVIEWS UROLOGY, 2010, 7 (10) :562-571
[25]   Prostate cancer:: Identification with combined diffusion-weighted MR imaging and 3D 1HMR spectroscopic imaging correlation with pathologic findings [J].
Mazaheri, Yousef ;
Shukla-Dave, Amita ;
Hricak, Hedvig ;
Fine, Samson W. ;
Zhang, Jingbo ;
Inurrigarro, Gloria ;
Moskowitz, Chaya S. ;
Ishill, Nicole M. ;
Reuter, Victor E. ;
Touijer, Karim ;
Zakian, Kristen L. ;
Koutcher, Jason A. .
RADIOLOGY, 2008, 246 (02) :480-488
[26]  
Noguchi M, 2000, CANCER, V89, P1056, DOI 10.1002/1097-0142(20000901)89:5<1056::AID-CNCR15>3.0.CO
[27]  
2-U
[28]   Diffusion-Weighted and Dynamic Contrast-Enhanced MRI of Prostate Cancer: Correlation of Quantitative MR Parameters With Gleason Score and Tumor Angiogenesis [J].
Oto, Aytekin ;
Yang, Cheng ;
Kayhan, Arda ;
Tretiakova, Maria ;
Antic, Tatjana ;
Schmid-Tannwald, Christine ;
Eggener, Scott ;
Karczmar, Gregory S. ;
Stadler, Walter M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (06) :1382-1390
[29]   Prostate Cancer: Differentiation of Central Gland Cancer from Benign Prostatic Hyperplasia by Using Diffusion-weighted and Dynamic Contrast-enhanced MR Imaging [J].
Oto, Aytekin ;
Kayhan, Arda ;
Jiang, Yulei ;
Tretiakova, Maria ;
Yang, Cheng ;
Antic, Tatjana ;
Dahi, Farid ;
Shalhav, Arieh L. ;
Karczmar, Gregory ;
Stadler, Walter M. .
RADIOLOGY, 2010, 257 (03) :715-723
[30]   MRI in the Detection of Prostate Cancer: Combined Apparent Diffusion Coefficient, Metabolite Ratio, and Vascular Parameters [J].
Riches, Sophie F. ;
Payne, Geoffrey S. ;
Morgan, Veronica A. ;
Sandhu, Samir ;
Fisher, Cyril ;
Germuska, Michael ;
Collins, David J. ;
Thompson, Alan ;
deSouza, Nandita M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) :1583-1591