Objective: Although transcranial magnetic stimulation (TMS) has been widely used to study motor cortex organization and excitability, the reliability of this technique has not been thoroughly investigated. Furthermore, previous reports of TMS reliability have been restricted to upper limb musculature. We sought to determine the test-retest reliability for TMS mapping of motor representations for swallowing musculature. Methods: Twenty healthy volunteers were tested twice over two weeks using TMS to determine motor threshold, map area, map volume, maximal MEP site location and maximal MEP site size for the suprahyoid complex and pharyngeal musculature. Results: Good test-retest reliability was found in both swallowing muscle sites for the following test parameters: motor map area, maximal MEP site location: lateral coordinate, maximal MEP site size and motor threshold (ICC = 0.76-0.98). Moderate reliability was observed for motor map volume and maximal MEP site location: anterior-posterior coordinate (ICC = 0.68-0.74). Conclusions: TMS assessments of motor representation size, location and excitability appear to be highly reproducible, although the reliability of these measures may vary according to the specific muscle under investigation. Significance: These works provide much needed psychometric data to validate the use of TMS to assess the cortical representation of swallowing musculature. Published by Elsevier Ireland Ltd. on behalf of International Federation of Clinical Neurophysiology.
引用
收藏
页码:2298 / 2303
页数:6
相关论文
共 33 条
[21]   Reliability of motor-evoked potentials during resting and active contraction conditions [J].
Kamen, G .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (09) :1574-1579
[22]   Reliability of intracortical and corticomotor excitability estimates obtained from the upper extremities in chronic stroke [J].
Koski, Lisa ;
Lin, Janice Chien-Ho ;
Wu, Allan D. ;
Winstein, Carolee J. .
NEUROSCIENCE RESEARCH, 2007, 58 (01) :19-31
[23]   Reliability of motor cortex transcranial magnetic stimulation in four muscle representations [J].
Malcolm, M. P. ;
Triggs, W. J. ;
Light, K. E. ;
Shechtman, O. ;
Khandekar, G. ;
Rothi, L. J. Gonzalez .
CLINICAL NEUROPHYSIOLOGY, 2006, 117 (05) :1037-1046
[24]  
McGraw KO, 1996, PSYCHOL METHODS, V1, P30, DOI 10.1037/1082-989X.1.4.390
[25]   Transcranial magnetic-stimulation mapping of the cortical topography of the human masseter muscle [J].
McMillan, AS ;
Watson, C ;
Walshaw, D .
ARCHIVES OF ORAL BIOLOGY, 1998, 43 (12) :925-931
[26]   A new method for reproducible coil positioning in transcranial magnetic stimulation mapping [J].
Miranda, PC ;
deCarvalho, M ;
Conceicao, I ;
Luis, MLS ;
DuclaSoares, E .
ELECTROMYOGRAPHY AND MOTOR CONTROL-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 105 (02) :116-123
[27]   RELIABILITY OF TRANSCRANIAL MAGNETIC STIMULATION FOR MAPPING THE HUMAN MOTOR CORTEX [J].
MORTIFEE, P ;
STEWART, H ;
SCHULZER, M ;
EISEN, A .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1994, 93 (02) :131-137
[28]   Assessing the temporal reproducibility of human esophageal motor-evoked potentials to transcranial magnetic stimulation [J].
Paine, P. A. ;
Aziz, Q. ;
Gardener, E. ;
Hobson, A. ;
Mistry, S. ;
Thompson, D. G. ;
Hamdy, S. .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2006, 23 (04) :374-380
[29]   Changes in pharyngeal corticobulbar excitability and swallowing behavior after oral stimulation [J].
Power, M ;
Fraser, C ;
Hobson, A ;
Rothwell, JC ;
Mistry, S ;
Nicholson, DA ;
Thompson, DG ;
Hamdy, S .
AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 2004, 286 (01) :G45-G50
[30]   Stability of maps of human motor cortex made with transcranial magnetic stimulation [J].
Uy, J ;
Ridding, MC ;
Miles, TS .
BRAIN TOPOGRAPHY, 2002, 14 (04) :293-297