HIGH-RESOLUTION COMPUTER DISPLAY OF PORTABLE, DIGITAL, CHEST RADIOGRAPHS OF ADULTS - SUITABILITY FOR PRIMARY INTERPRETATION

被引:27
作者
FRANK, MS [1 ]
JOST, RG [1 ]
MOLINA, PL [1 ]
ANDERSON, DJ [1 ]
SOLOMON, SL [1 ]
WHITMAN, RA [1 ]
MOORE, SM [1 ]
机构
[1] EDWARD MALLINCKRODT INST RADIOL,ST LOUIS,MO 63110
关键词
D O I
10.2214/ajr.160.3.8430538
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The suitability of using a high-resolution computer-display system for primary interpretation of adult chest radiographs obtained with portable apparatus and storage phosphor technology was evaluated with receiver operating characteristic analysis and subjective methods. MATERIALS AND METHODS. Sixty portable digital chest radiographs showing abnormalities that approached the resolution limits of our computed radiography system were selected. The original digital data making up the 2140 x 1760 x 10 bit images were transferred to a cathode ray tube (CRT) display system composed of two Megascan monitors. Postprocessing rendered two images, one for each monitor, to emulate the two-on-one hard-copy format produced by the computed radiography system. Each image set was interpreted independently by three radiologists experienced with hard-copy format. Limited level and window adjustments were allowed during CRT interpretation. For both CRT and hard-copy display, images were graded on the basis of the interpreter's confidence in the presence of pneumothorax and parenchymal abnormalities. Three types of foreign devices were subjectively analyzed: endotracheal tubes, nasogastric tubes, and temporary epicardial pacer wires. RESULTS. No significant differences were found in detecting pneumothorax or focal infiltrates. One radiologist found the hard copy better for detecting diffuse infiltrates (p = .02); two radiologists favored CRT for visualizing nasogastric tubes (p < .005, p < .02); and one radiologist favored CRT for visualizing temporary epicardial pacer wires (p = .05). CONCLUSION. We conclude that an optimized high-resolution CRT system is quite promising for primary interpretation of digital portable chest radiographs, but further investigation and greater statistical power are necessary to confirm our results.
引用
收藏
页码:473 / 477
页数:5
相关论文
共 19 条
[1]   MEASURING OBSERVER PERFORMANCE BY ROC ANALYSIS - INDICATIONS AND COMPLICATIONS [J].
BERBAUM, KS ;
DORFMAN, DD ;
FRANKEN, EA .
INVESTIGATIVE RADIOLOGY, 1989, 24 (03) :228-233
[2]   MR EXAMINATION OF THE KNEE - INTERPRETATION WITH MULTISCREEN DIGITAL WORKSTATION VS HARD-COPY FORMAT [J].
BROWN, JJ ;
MALCHOW, SC ;
TOTTY, WG ;
WILSON, AJ ;
LEE, JKT ;
VANNIER, MW ;
JOST, RG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :81-85
[3]   CLINICAL-EVALUATION OF A RADIOLOGIC PICTURE ARCHIVING AND COMMUNICATION-SYSTEM FOR A CORONARY-CARE UNIT [J].
CHO, PS ;
HUANG, HK ;
TILLISCH, J ;
KANGARLOO, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (04) :823-827
[4]   ASSESSMENT OF COSTS AND BENEFITS IN THE INTRODUCTION OF DIGITAL RADIOLOGY SYSTEMS [J].
CROWE, BL ;
HAILEY, DM ;
CARTER, R .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1992, 30 (01) :17-25
[5]   CLINICAL-DIAGNOSIS FROM DIGITAL DISPLAYS - PRELIMINARY FINDINGS OF THE ST-MARYS EVALUATION PROJECT [J].
DAWOOD, RM ;
CRAIG, JOMC ;
HIGHMAN, JH ;
WADSWORTH, J ;
GLASS, HI ;
TODDPOKROPEK, A ;
CUNNINGHAM, DA ;
STEVENS, JM ;
ALKUTOUBI, A ;
KERSLAKE, RW ;
CHOUDHRI, AH ;
BARBER, CJ ;
CROFTON, MC ;
PORTER, AW .
CLINICAL RADIOLOGY, 1989, 40 (04) :369-373
[6]   RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD [J].
DORFMAN, DD ;
BERBAUM, KS ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :723-731
[7]   HIGH-RESOLUTION DIGITAL IMAGING WITH STORAGE PHOSPHORS [J].
FUHRMAN, CR ;
GUR, D ;
SCHAETZING, R .
JOURNAL OF THORACIC IMAGING, 1990, 5 (01) :21-30
[8]  
GLANTZ SA, 1992, PRIMER BIOSTATISTICS, P311
[9]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[10]   COMPARISON OF 2048-LINE DIGITAL-DISPLAY FORMATS AND CONVENTIONAL RADIOGRAPHS - AN ROC STUDY [J].
HAYRAPETIAN, A ;
ABERLE, DR ;
HUANG, HK ;
FISKE, R ;
MORIOKA, C ;
VALENTINO, D ;
BOECHAT, MI .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (05) :1113-1118