DESIGN IMPROVEMENTS OF THE HIA-VAD BASED ON ANIMAL-EXPERIMENTS

被引:16
作者
EILERS, R [1 ]
HARBOTT, P [1 ]
REUL, H [1 ]
RAKHORST, G [1 ]
RAU, G [1 ]
机构
[1] UNIV GRONINGEN,CTR BIOMED TECHNOL,9700 AB GRONINGEN,NETHERLANDS
关键词
VENTRICULAR ASSIST DEVICES; DEVELOPMENT; DESIGN; IN-VITRO TEST; FEM ANALYSIS;
D O I
10.1111/j.1525-1594.1994.tb03362.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Since 1990, development of the Helmholtz-Institute at Aachen ventricular assist device (HIA-VAD) was mainly based on animal tests performed at the University of Groningen. Although various in vitro tests had been performed previously, animal testing resulted in significant improvements of the HIA-VAD with regard to hemodynamics and pump handling. The most important design improvement was a new trileaflet polyurethane valve, which was designed as a blood-pump valve with an emphasis on opening behavior and flow resistance. Excellent hydrodynamic performance and sufficient durability of this new valve were confirmed by various in vitro tests. Further design and manufacturing improvements resulted in a completely transparent pump, which can be easily deaired and optically controlled. Final pump design was evaluated during subsequent animal tests, and the results are very promising in view of an efficient cardiac support system.
引用
收藏
页码:473 / 478
页数:6
相关论文
共 15 条
[1]   VELOCITY AND SHEAR-STRESS DISTRIBUTION DOWNSTREAM OF MECHANICAL HEART-VALVES IN PULSATILE FLOW [J].
GIERSIEPEN, M ;
KRAUSE, U ;
KNOTT, E ;
REUL, H ;
RAU, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1989, 12 (04) :261-269
[2]  
GIERSIEPEN M, 1988, THESIS TU AACHEN
[3]   INVITRO FATIGUE TEST-RESULTS AND HEMOLYSIS OF A FLEXIBLE LEAFLET VALVE [J].
HAUSSINGER, G ;
REUL, H .
BIOMEDIZINISCHE TECHNIK, 1981, 26 (03) :40-43
[4]  
HEROLD M, 1988, THESIS TU AACHEN
[5]  
JANSEN J, 1990, THESIS TU AACHEN
[6]   NEW METHODS FOR THE DEVELOPMENT OF PNEUMATIC DISPLACEMENT PUMPS FOR CARDIAC ASSIST [J].
KNIERBEIN, B ;
ROSARIUS, N ;
REUL, H ;
RAU, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1990, 13 (11) :751-759
[7]   CAD-DESIGN, STRESS-ANALYSIS AND INVITRO EVALUATION OF 3 LEAFLET BLOOD-PUMP VALVES [J].
KNIERBEIN, B ;
ROSARIUS, N ;
UNGER, A ;
REUL, H ;
RAU, G .
JOURNAL OF BIOMEDICAL ENGINEERING, 1992, 14 (04) :275-286
[8]  
KNIERBEIN B, 1990, THESIS TU AACHEN
[9]   COMPARATIVE-STUDY OF THE FUNCTION OF THE ABIOMED POLYURETHANE HEART-VALVE FOR USE IN LEFT-VENTRICULAR ASSIST DEVICES [J].
LEAT, ME ;
FISHER, J .
JOURNAL OF BIOMEDICAL ENGINEERING, 1993, 15 (06) :516-520
[10]  
RAKHORST G, 1994, IN PRESS J THORAC CA