BIFUNCTIONAL LANGMUIR-BLODGETT-FILM FOR ENZYME IMMOBILIZATION AND AMPEROMETRIC BIOSENSOR SENSITIZATION

被引:42
作者
TATSUMA, T
TSUZUKI, H
OKAWA, Y
YOSHIDA, S
WATANABE, T
机构
[1] Institute of Industrial Science, University of Tokyo Roppongi, Minato-ku, Tokyo
关键词
D O I
10.1016/0040-6090(91)90550-H
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A Langmuir-Blodgett (LB) film consisting of octadecylamine as the binding site for the enzyme molecule, an amphiphilic ferrocene derivative as the electron mediator, and octadecanol as the matrix for these molecules was deposited on a hydrophobized tin oxide (SnO2) electrode. Glucose oxidase (GOx) was then covalently immobilized on the film via glutaraldehyde, and the GOx electrode thus obtained worked as an amperometric glucose sensor based on the oxidation of hydrogen peroxide liberated by the enzymatic reaction. The sensitivity of this sensor was about twice as high as that of a GOx electrode prepared with the same LB film as above but without the ferrocene. The sensitizing effect of ferrocene was attributed to its capability of electron mediation between hydrogen peroxide and the SnO2 electrode.
引用
收藏
页码:145 / 150
页数:6
相关论文
共 9 条
[1]   PENICILLIN SENSORS BASED ON AN ION-SENSITIVE FIELD-EFFECT TRANSISTOR COATED WITH STEARIC-ACID LANGMUIR-BLODGETT MEMBRANE [J].
ANZAI, J ;
HASHIMOTO, J ;
OSA, T ;
MATSUO, T .
ANALYTICAL SCIENCES, 1988, 4 (03) :247-250
[2]   CHARACTERIZATION OF ELECTROACTIVE LANGMUIR-BLODGETT MONOLAYERS OF (FERROCENYLMETHYL)DIMETHYLOCTADECYLAMMONIUM SULFATE AT GOLD AND AIR WATER INTERFACES [J].
FACCI, JS ;
FALCIGNO, PA ;
GOLD, JM .
LANGMUIR, 1986, 2 (06) :732-738
[3]   NEW TECHNIQUE FOR INVESTIGATING LIPID PROTEIN FILMS [J].
FROMHERZ, P .
BIOCHIMICA ET BIOPHYSICA ACTA, 1971, 225 (02) :382-&
[4]   PREPARATIONS OF LANGMUIR-BLODGETT FILMS OF ENZYME LIPID COMPLEXES - A GLUCOSE SENSOR MEMBRANE [J].
OKAHATA, Y ;
TSURUTA, T ;
IJIRO, K ;
ARIGA, K .
THIN SOLID FILMS, 1989, 180 :65-72
[5]   GLUCOSE SENSOR CARRYING MONOMOLECULAR LAYER OF GLUCOSE-OXIDASE COVALENTLY BOUND TO TIN(IV) OXIDE ELECTRODE [J].
OKAWA, Y ;
TSUZUKI, H ;
YOSHIDA, S ;
WATANABE, T .
ANALYTICAL SCIENCES, 1989, 5 (05) :507-512
[6]   ENZYME-IMMOBILIZED LANGMUIR-BLODGETT FILM FOR A BIOSENSOR [J].
SRIYUDTHSAK, M ;
YAMAGISHI, H ;
MORIIZUMI, T .
THIN SOLID FILMS, 1988, 160 (1-2) :463-469
[7]   ENZYME MONOLAYER-MODIFIED AND BILAYER-MODIFIED TIN OXIDE ELECTRODES FOR THE DETERMINATION OF HYDROGEN-PEROXIDE AND GLUCOSE [J].
TATSUMA, T ;
OKAWA, Y ;
WATANABE, T .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2352-2355
[8]  
Trurnit H J, 1960, J COLLOID SCI, V15, P1, DOI DOI 10.1016/0095-8522(60)90002-7
[9]   A NOVEL GLUCOSE SENSOR WITH A GLUCOSE-OXIDASE MONOLAYER IMMOBILIZED BY THE LANGMUIR-BLODGETT TECHNIQUE [J].
TSUZUKI, H ;
WATANABE, T ;
OKAWA, Y ;
YOSHIDA, S ;
YANO, S ;
KOUMOTO, K ;
KOMIYAMA, M ;
NIHEI, Y .
CHEMISTRY LETTERS, 1988, (08) :1265-1268