TECHNICAL OPTIMIZATION OF SPIRAL CT FOR DEPICTION OF RENAL-ARTERY STENOSIS - IN-VITRO ANALYSIS

被引:96
作者
BRINK, JA
LIM, JT
WANG, G
HEIKEN, JP
DEYOE, LA
VANNIER, MW
机构
[1] Department of Radiology, Mallinckrodt Institute of Radiology, Washington Univ. School of Medicine, St Louis, MO 63110
关键词
COMPUTED TOMOGRAPHY (CT); HELICAL; RENAL ARTERIES; STENOSIS OR OBSTRUCTION;
D O I
10.1148/radiology.194.1.7997544
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine empirically the effect of scan parameters and postprocessing techniques on depiction accuracy of renal artery stenosis with spiral computed tomographic angiography. MATERIALS AND METHODS: Critical(85%) and noncritical (45%) stenoses in the coronal plane were modeled in vitro and scanned with 12 combinations of collimation (1, 2, or 3 mm), table increment (pitch = 1-2),2 and reconstruction interval (0.5 or 1.0 mm). Five test images were generated for each spiral scanning technique: multiplanar reformation (MPR), maximum-intensity projections (MIPs: coronal MIP [MIPcor], coronal MIP targeted to phantom vessel and surrounding fat [target MIPcor]), transaxial imaging, and transaxial MIP. RESULTS: With 3-mm collimation, critical stenosis was overestimated to the point of occlusion on MIPcor images and underestimated on MPR and target MIPcor images. A 0.5-mm reconstruction interval was marginally beneficial for 1- and 2-mm collimation, but noise was prohibitive with 1-mm collimation. CONCLUSION: Critical renal artery stenosis is best depicted with 2-mm collimation, 2-4-mm table increment, and 1-mm reconstruction interval.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 14 条
[1]   ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS [J].
ANDERSON, CM ;
SALONER, D ;
TSURUDA, JS ;
SHAPEERO, LG ;
LEE, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) :623-629
[2]   SPIRAL CT - DECREASED SPATIAL-RESOLUTION INVIVO DUE TO BROADENING OF SECTION-SENSITIVITY PROFILE [J].
BRINK, JA ;
HEIKEN, JP ;
BALFE, DM ;
SAGEL, SS ;
DICROCE, J ;
VANNIER, MW .
RADIOLOGY, 1992, 185 (02) :469-474
[3]   CONTRAST-TO-NOISE RATIOS IN MAXIMUM INTENSITY PROJECTION IMAGES [J].
BROWN, DG ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :130-137
[4]   VOLUME RENDERING AND CONNECTIVITY ALGORITHMS FOR MR ANGIOGRAPHY [J].
CLINE, HE ;
DUMOULIN, CL ;
LORENSEN, WE ;
SOUZA, SP ;
ADAMS, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :384-394
[5]   NEWER TESTS FOR THE DIAGNOSIS OF RENOVASCULAR DISEASE [J].
DAVIDSON, RA ;
WILCOX, CS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 268 (23) :3353-3358
[6]   CT ANGIOGRAPHY - APPLICATION TO THE EVALUATION OF CAROTID-ARTERY STENOSIS [J].
DILLON, EH ;
VANLEEUWEN, MS ;
FERNANDEZ, MA ;
EIKELBOOM, BC ;
MALI, WPTM .
RADIOLOGY, 1993, 189 (01) :211-219
[7]   RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY [J].
GALANSKI, M ;
PROKOP, M ;
CHAVAN, A ;
SCHAEFER, CM ;
JANDELEIT, K ;
NISCHELSKY, JE .
RADIOLOGY, 1993, 189 (01) :185-192
[8]   LUMEN DEFINITION IN MR ANGIOGRAPHY [J].
LIN, WL ;
HAACKE, EM ;
SMITH, AS .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03) :327-336
[9]   EVALUATION OF SECTION SENSITIVITY PROFILES AND IMAGE NOISE IN SPIRAL CT [J].
POLACIN, A ;
KALENDER, WA ;
MARCHAL, G .
RADIOLOGY, 1992, 185 (01) :29-35
[10]   3-DIMENSIONAL SPIRAL CT ANGIOGRAPHY OF THE ABDOMEN - INITIAL CLINICAL-EXPERIENCE [J].
RUBIN, GD ;
DAKE, MD ;
NAPEL, SA ;
MCDONNELL, CH ;
JEFFREY, RB .
RADIOLOGY, 1993, 186 (01) :147-152