SECONDARY-ELECTRON RESOLVED MASS-SPECTROMETRY OF ELECTROSPRAYED IONS

被引:25
作者
AXELSSON, J
REIMANN, CT
SUNDQVIST, BUR
机构
[1] Division of Ion Physics, Department of Radiation Sciences, Uppsala University, S-751 21 Uppsala
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1994年 / 133卷 / 2-3期
关键词
SECONDARY ELECTRON EMISSION; MACROMOLECULE; ELECTROSPRAY; MASS SPECTRUM;
D O I
10.1016/0168-1176(94)03956-9
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
An important process in mass spectrometric techniques is the registration of analyte ions at appropriate detector surfaces. Although the nature of the ion-surface interaction can introduce bias in the detection process, such biases can also be exploited to yield complementary information about the detected ions. In this paper, results are presented on the secondary electron yield from impacts of electrosprayed macro-molecular ions on an Al2O3 surface. The secondary electron yield is parametrized as a function of ion mass and velocity. This information is used to acquire mass information (in contrast to the mass-to-charge ratio information gained in quadrupoles and magnetic sector instruments) from the secondary electron yield measured in the detection part of a mass spectrometer. The primary ions are filtered in a scanning mass-to-charge-ratio filter at the same time as mass information from the secondary electron yield is collected. With this method, peaks caused by certain molecules present at low concentrations can be enhanced, and discrimination against low mass ''noise'' can be achieved. Also, peaks with the same mass-to-charge ratio but distinctly different masses can be separately identified. Several practical applications are demonstrated, and evidence for gas-phase fragmentation of large poly(ethylene glycols) is presented.
引用
收藏
页码:141 / 155
页数:15
相关论文
共 27 条
[1]  
ALEXANDROV ML, 1990, RAPID COMMUN MASS SP, V4, P13
[2]   DESIGN AND PERFORMANCE OF A NOVEL ELECTROSPRAY INTERFACE [J].
ALLEN, MH ;
VESTAL, ML .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (01) :18-26
[3]  
AXELSSON D, UNPUB PHYS RES B
[4]  
AXELSSON J, IN PRESS NUCL INSTRU
[5]  
AXELSSON J, UNPUB
[6]  
AXELSSON J, 1993, 41ST ASMS C MASS SPE
[7]   IMPROVED FOURIER-TRANSFORM ION-CYCLOTRON-RESONANCE MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (02) :190-192
[9]   PULSE AMPLITUDE ANALYSIS - A NEW DIMENSION IN SINGLE-ION TIME-OF-FLIGHT MASS-SPECTROMETRY [J].
BONDARENKO, PV ;
GRANT, PG ;
MACFARLANE, RD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 131 :181-192
[10]  
COOKS RG, 1991, RAPID COMMUN MASS SP, V5, P93