TECHNICAL AND PRACTICAL ASPECTS OF MAGNETIC NERVE-STIMULATION

被引:174
作者
JALINOUS, R [1 ]
机构
[1] MAGSTIM CO LTD,DEPT ENGN,WHITLAND SA34 0HR,WALES
关键词
MAGNETIC STIMULATION; NERVES; MAGNETIC FIELDS; DOUBLE COILS; FIGURE-8-COILS; MOTOR CORTEX;
D O I
10.1097/00004691-199101000-00004
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Magnetic stimulators consist of a high-voltage (400 V to more than 3 kV), high-current (4 kA to more than 20 kA) discharge system producing a brief pulse of magnetic field (1-10 T lasting up to a few milliseconds). In order to ensure safety and reliability, care has to be taken in the construction of magnetic stimulators and especially their stimulating coils, which may come into contact with the patient, by the use of adequate mechanical and electrical insulation and the incorporation of sensors to monitor temperature, voltage, etc. Where possible, equipment should be manufactured to comply with safety standards such as UL504 and IEC601. The effectiveness of a magnetic stimulator depends on many parameters such as the maximization of the peak coil energy, fast magnetic field rise times, and good coil design. It is also important to choose a coil based on its intended clinical application and not simply on account of its high magnetic field strength. A small coil, producing a high surface magnetic field, is suitable in the stimulation of superficial nerves, whereas a larger coil, with a low magnetic field intensity, may well be more suitable for the stimulation of deep nerves. Double, figure-eight, or butterfly coils produce more localised induced currents allowing for more selective stimulation. The exposure of the brain to high magnetic field strengths can also be reduced by using larger coils.
引用
收藏
页码:10 / 25
页数:16
相关论文
共 15 条
[1]  
AGNEW WF, 1987, NEUROSURGERY, V20, P143
[2]  
BARKER AT, 1985, LANCET, V1, P1106
[3]  
BARKER AT, 1990, J PHYSIOL-LONDON, V423, P66
[4]  
Barker AT, 1985, J PHYSL, V369, P3
[5]  
BARKER AT, 1989, MAGNETIC STIMULATION, P55
[6]  
Bickford R., 1965, 6TH INT C MED EL BIO, P112
[7]   TRANSCHEST MAGNETIC (EDDY-CURRENT) STIMULATION OF THE DOG HEART [J].
BOURLAND, JD ;
MOUCHAWAR, GA ;
NYENHUIS, JA ;
GEDDES, LA ;
FOSTER, KS ;
JONES, JT ;
GRABER, GP .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (02) :196-198
[8]  
DARSONVAL A, 1896, C R SOC BIOL, V3, P450
[9]   SPECIFIC RESISTANCE OF BIOLOGICAL MATERIAL-A COMPENDUM OF DATA FOR BIOMEDICAL ENGINEER AND PHYSIOLOGIST [J].
GEDDES, LA ;
BAKER, LE .
MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (03) :271-&
[10]  
HOMBERG V, 1989, LANCET, V2, P1223