RESIDENTIAL AIR EXCHANGE-RATES IN THE UNITED-STATES - EMPIRICAL AND ESTIMATED PARAMETRIC DISTRIBUTIONS BY SEASON AND CLIMATIC REGION

被引:188
作者
MURRAY, DM [1 ]
BURMASTER, DE [1 ]
机构
[1] ALCEON CORP,CAMBRIDGE,MA 02238
关键词
AIR EXCHANGE RATES; AIR CHANGES PER HOUR; INDOOR AIR; DISTRIBUTIONS; EXPOSURE; MONTE CARLO;
D O I
10.1111/j.1539-6924.1995.tb00338.x
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The purpose of this paper is to undertake a statistical analysis to specify empirical distributions and to estimate univariate parametric probability distributions for air exchange rates for residential structures in the United States. To achieve this goal, we used data compiled by the Brookhaven National Laboratory using a method known as the perfluorocarbon tracer (PFT) technique. While these data are not fully representative of all areas of the country or all housing types, they are judged to be by far the best available. The analysis is characterized by four key points: the use of data for 2,844 households; a four-region breakdown based on heating degree days, a best available measure of climatic factors affecting air exchange rates; estimation of lognormal distributions as well as provision of empirical (frequency) distributions; and provision of these distributions for all of the data, for the data segmented by the four regions, for the data segmented by the four seasons, and for the data segmented by a 16 region by season breakdown. Except in a few cases, primarily for small sample sizes, air exchange rates were found to be well fit by lognormal distributions (adjusted R(2) 0.95). The empirical or lognormal distributions may be used in indoor air models or as input variables for probabilistic human health risk assessments.
引用
收藏
页码:459 / 465
页数:7
相关论文
共 13 条
[1]  
Benjamin J. R., 1970, PROBABILITY STATISTI
[2]   A SUGGESTION FOR USING POWERFUL AND INFORMATIVE TESTS OF NORMALITY [J].
DAGOSTINO, RB ;
BELANGER, A ;
DAGOSTINO, RB .
AMERICAN STATISTICIAN, 1990, 44 (04) :316-321
[3]  
Dietz RN, 1986, MEASURED AIR LEAKAGE, P203
[4]  
DUPONT P, 1989, RESIDENTIAL INDOOR A
[5]  
Gilbert R. O., 1987, STATISTICAL METHODS
[6]  
GOODRICH RW, 1988, DATABASE PFT VENTILA
[7]   TRACER-GAS TECHNIQUES FOR MEASURING VENTILATION IN A SINGLE ZONE [J].
SHERMAN, MH .
BUILDING AND ENVIRONMENT, 1990, 25 (04) :365-374
[8]   ANALYSIS OF ERRORS ASSOCIATED WITH PASSIVE VENTILATION MEASUREMENT TECHNIQUES [J].
SHERMAN, MH .
BUILDING AND ENVIRONMENT, 1989, 24 (02) :131-139
[9]  
STAMPER E, 1979, HDB CONDITIONING HEA
[10]  
*SYST INC, 1992, SYST SYGR SYST GRAPH