A CONDUCTIVE POLYMER SENSOR FOR MEASURING EXTERNAL FINGER FORCES

被引:66
作者
JENSEN, TR
RADWIN, RG
WEBSTER, JG
机构
[1] UNIV WISCONSIN,DEPT IND ENGN,1513 UNIV AVE,MADISON,WI 53706
[2] UNIV WISCONSIN,DEPT ELECT & COMP ENGN,MADISON,WI 53706
关键词
D O I
10.1016/0021-9290(91)90310-J
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper describes the construction and use of a durable and thin force sensor that can be attached to the palmar surface of the fingers and hands for studying the biomechanics of grasp and for use in hand injury rehabilitation. These force sensors were constructed using a modified commercially available conductive polymer pressure sensing element and installing an epoxy dome for directing applied forces through a 12 mm diameter active sensing area. The installation of an epoxy dome was effective for making the sensors insensitive to contact surfaces varying from 25 to 1100 mm2 and a 16 mm radius surface curved convex towards the finger. The completed sensors were only 1.8 mm thick and capable of being taped to the distal phalangeal finger pads. They were calibrated on the hand by pinching a strain gage dynamometer. The useful range was between 0 and 30 N with an accuracy of 1 N for both static loading and normal dynamic grasp activities. The sensor time constant was 0.54 ms for a step force input. Because of varying offset voltages every time the sensors were attached, these sensors should be calibrated on the hand before each use. The sensors were used for measuring finger forces during controlled pinching and lifting tasks, and during ordinary grasping activities, such as picking up a book or a box, where the useful force range and response for these sensors were adequate.
引用
收藏
页码:851 / &
相关论文
共 20 条
[1]   VARIATION OF FINGER FORCES IN MAXIMAL ISOMETRIC GRASP TESTS ON A RANGE OF CYLINDER DIAMETERS [J].
AMIS, AA .
JOURNAL OF BIOMEDICAL ENGINEERING, 1987, 9 (04) :313-320
[2]   FORCES IN THE NORMAL AND ABNORMAL HAND [J].
AN, KN ;
CHAO, EY ;
COONEY, WP ;
LINSCHEID, RL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (02) :202-211
[3]   METHODOLOGY FOR DOCUMENTING HAND POSITIONS AND FORCES DURING MANUAL WORK [J].
ARMSTRONG, TJ ;
CHAFFIN, DB ;
FOULKE, JA .
JOURNAL OF BIOMECHANICS, 1979, 12 (02) :131-133
[4]   A MICROCOMPUTER SYSTEM FOR THE MEASUREMENT OF FINGER FORCES [J].
BOLSINGER, PP ;
MAI, N .
JOURNAL OF BIOMEDICAL ENGINEERING, 1985, 7 (01) :51-55
[5]   SENSORS FOR USE WITH FUNCTIONAL NEUROMUSCULAR STIMULATION [J].
CRAGO, PE ;
CHIZECK, HJ ;
NEUMAN, MR ;
HAMBRECHT, FT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) :256-268
[6]  
DICKSON RA, 1972, BIOMED ENG, V7, P270
[7]   ISOLATED FINGER FLEXION FORCE - A METHODOLOGICAL STUDY [J].
EJESKAR, A ;
ORTENGREN, R .
HAND, 1981, 13 (03) :223-230
[8]  
FELLOWS GL, 1989, 33RD P HUM FACT SOC, P713
[9]   CLINICAL-ASSESSMENT OF HAND STRENGTH USING A MICROCOMPUTER [J].
JAIN, AS ;
HENNEDY, JA ;
CARUS, DA .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1985, 10B (03) :315-318
[10]  
MAALEJ N, 1988, P IEEE ENG MED BIO S, V10, P770