MAGNETIC-RESONANCE ANGIOGRAPHY (MRA) OF THE CIRCLE OF WILLIS - A PROSPECTIVE COMPARISON WITH CONVENTIONAL ANGIOGRAPHY IN 54 SUBJECTS

被引:61
作者
PATRUX, B
LAISSY, JP
JOUINI, S
KAWIECKI, W
COTY, P
THIEBOT, J
机构
[1] CHU BICHAT,DEPT RADIOL,F-75018 PARIS,FRANCE
[2] CHU CHARLES NICOLLE,ROUEN,FRANCE
[3] SIEMENS MED SYST INC,ST DENIS,FRANCE
关键词
CIRCLE OF WILLIS; FUNCTIONAL STUDIES; ANATOMY; CEREBRAL ANGIOGRAPHY; MAGNETIC RESONANCE ANGIOGRAPHY; BRAIN; ISCHEMIA;
D O I
10.1007/BF00588129
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We prospectively correlated the findings of magnetic resonance angiography (MRA) with those of transfemoral four-vessel angiography in 54 patients to investigate the direction of now within the circle of Willis. Our primary goal was to assess the direction of flow using the size of the vessel and signal intensity, without saturation techniques. Analysis of the circle of Willis, especially the communicating arteries, was performed double-blind by two groups of two radiologists. Three types of arteries were identified: high now or cross-cerebral circulation, patent and nonvisualised arteries. Cerebral angiography was the standard for comparison between the two methods. MRA did not reveal any arteries invisible on angiography, thus providing a specificity of 100%. The sensitivity of MRA was 89.2% for the anterior and 81.3% for the posterior communicating arteries, and 100% for the anterior, middle and posterior cerebral arteries. MRA was shown to be a useful technique for the assessment of patency of the circle of Willis.
引用
收藏
页码:193 / 197
页数:5
相关论文
共 18 条
[1]  
BERENSTEIN A, 1988, RADIOL CLIN N AM, V26, P1143
[2]   MAGNETIC-RESONANCE-IMAGING OF FLOW DYNAMICS IN THE CIRCLE OF WILLIS [J].
EDELMAN, RR ;
MATTLE, HP ;
OREILLY, GV ;
WENTZ, KU ;
LIU, C ;
ZHAO, B .
STROKE, 1990, 21 (01) :56-65
[3]   MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MATTLE, HP ;
ATKINSON, DJ ;
HOOGEWOUD, HM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (05) :937-946
[4]  
ESKRIDGE JM, 1991, AM J NEURORADIOL, V12, P1053
[5]   INTERVENTIONAL NEURORADIOLOGY [J].
ESKRIDGE, JM .
RADIOLOGY, 1989, 172 (03) :991-1006
[6]   EVALUATION OF CEREBROVASCULAR-DISEASE BY COMBINED EXTRACRANIAL AND TRANSCRANIAL DOPPLER SONOGRAPHY EXPERIENCE IN 1,039 PATIENTS [J].
GROLIMUND, P ;
SEILER, RW ;
AASLID, R ;
HUBER, P ;
ZURBRUEGG, H .
STROKE, 1987, 18 (06) :1018-1024
[7]   INTRACRANIAL ANEURYSMS AND VASCULAR MALFORMATIONS - COMPARISON OF TIME-OF-FLIGHT AND PHASE-CONTRAST MR ANGIOGRAPHY [J].
HUSTON, J ;
RUFENACHT, DA ;
EHMAN, RL ;
WIEBERS, DO .
RADIOLOGY, 1991, 181 (03) :721-730
[8]   MR ANGIOGRAPHY WITH TWO-DIMENSIONAL ACQUISITION AND 3-DIMENSIONAL DISPLAY - WORK IN PROGRESS [J].
KELLER, PJ ;
DRAYER, BP ;
FRAM, EK ;
WILLIAMS, KD ;
DUMOULIN, CL ;
SOUZA, SP .
RADIOLOGY, 1989, 173 (02) :527-532
[9]  
LEWIN JS, 1991, AM J NEURORADIOL, V12, P1133
[10]  
LITT AW, 1991, AM J NEURORADIOL, V12, P149