SPECTRAL CHARACTERISTICS OF EMBOLIC HEART SOUNDS DETECTED BY PRECORDIAL DOPPLER ULTRASOUND DURING VENOUS AIR-EMBOLISM IN DOGS

被引:2
作者
LUI, PW
LIN, YM
CHAN, FHY
TSOU, MY
WANG, S
LAM, FK
POON, PWF
机构
[1] UNIV HONG KONG, FAC MED, DEPT PHYSIOL, SASSOON RD, HONG KONG, HONG KONG
[2] NATL YANG MING MED COLL, TAIPEI, TAIWAN
[3] VET GEN HOSP, TAIPEI, TAIWAN
[4] UNIV HONG KONG, FAC MED, DEPT ELECTR ENGN, HONG KONG, HONG KONG
关键词
EMBOLISM; VENOUS AIR; MONITORING; PRECORDIAL DOPPLER ULTRASOUND;
D O I
10.1093/bja/71.5.689
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We have studied the frequency spectrum of embolic heart sounds as detected by precordial Doppler ultrasound after injecting air 0.01-0.1 ml into the external jugular vein of anaesthetized dogs (n = 7). At volumes of 0.05 ml and greater, there was a significant increase in both the maximum frequency of the spectrum and the power of those high frequency components to greater than control values. Both changes correlated significantly with the volume of air injected (P < 0.05). With repeated injections of air at 5-min intervals, there was a sma# increase in the high frequency components in the control signal between injections (P < 0.05). We conclude that such spectral changes could be used to quantify the volume of air in transit through the heart, and to reflect the short-term history of venous air embolism.
引用
收藏
页码:689 / 695
页数:7
相关论文
共 12 条
[1]  
BUNEGIN BS, 1991, ANESTHESIOLOGY, V75, pA471
[2]   COMPARISON OF VENOUS AIR-EMBOLISM MONITORING METHODS IN SUPINE DOGS [J].
ENGLISH, JB ;
WESTENSKOW, D ;
HODGES, MR ;
STANLEY, TH .
ANESTHESIOLOGY, 1978, 48 (06) :425-429
[3]   A HIGH-RESOLUTION DATA-ADAPTIVE TIME FREQUENCY REPRESENTATION [J].
JONES, DL ;
PARKS, TW .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1990, 38 (12) :2127-2135
[4]   AN APPLICATION OF SIGNAL PROCESSING TECHNIQUES TO STUDY OF MYOELECTRIC SIGNALS [J].
KWATNY, E ;
THOMAS, DH ;
KWATNY, HG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1970, BM17 (04) :303-+
[5]  
LUI PW, 1992, P BIOMEDICAL ENG HON, V1, P120
[6]   PRECORDIAL ULTRASONIC MONITORING DURING CESAREAN DELIVERY [J].
MALINOW, AM ;
NAULTY, JS ;
HUNT, CO ;
DATTA, S ;
OSTHEIMER, GW .
ANESTHESIOLOGY, 1987, 66 (06) :816-819
[7]   COUNTING BUBBLES ACOUSTICALLY - REVIEW [J].
MEDWIN, H .
ULTRASONICS, 1977, 15 (01) :7-13
[8]   EVALUATION OF AN ULTRASONIC DEVICE (DOPPLER) FOR DIAGNOSIS OF VENOUS AIR EMBOLISM [J].
MICHENFELDER, JD ;
MILLER, RH ;
GRONERT, GA .
ANESTHESIOLOGY, 1972, 36 (02) :164-+
[9]   A TRANSMISSION-LINE MODELING APPROACH TO THE INTERPRETATION OF UTERINE DOPPLER WAVEFORMS [J].
MO, LYL ;
BASCOM, PAJ ;
RITCHIE, K ;
MCCOWAN, LME .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (05) :365-376
[10]  
SHERRIFF S, 1989, CARDIOVASCULAR APPLI, P15