A SINGLE LASER FLOW-CYTOMETRY METHOD TO EVALUATE THE BINDING OF 3 ANTIBODIES

被引:10
作者
MAURER, D [1 ]
FELZMANN, T [1 ]
KNAPP, W [1 ]
机构
[1] UNIV VIENNA,SFI,VIENNA INT RES COOPERAT CTR,INST IMMUNOL,BRUNNERSTR 59,A-1235 VIENNA,AUSTRIA
关键词
FLOW CYTOMETRY; STAINING PARAMETER; SINGLE LASER MULTIPARAMETER ANALYSIS;
D O I
10.1016/0022-1759(90)90254-S
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Here we describe a flow cytometry method which permits the collection of data regarding three staining parameters of a single cell from a suitable combination of dual parameter stainings using PE- and FITC-labelled mABs and a single argon laser. The technique neither requires a third dye with non-overlapping emission spectra nor a second light source. In order to test the accuracy of this method, we compared data calculated using this triple parameter analysis with data obtained by double staining a presorted population homogeneously positive for one parameter. In experiments using either resting or in vitro activated T cells, the percentages obtained with both methods were identical (P > 0.05). Using this method we tested which T cell sub-subpopulation is responsible for the weak CD25 (IL-2R-alpha) expression constantly associated with freshly isolated human T cells and concluded that it is predominantly expressed on the CD4+ CD45RO+ (CD4 positive memory) T cell subpopulation.
引用
收藏
页码:43 / 47
页数:5
相关论文
共 14 条
[1]   HUMAN T-CELL SUBSETS [J].
BEVERLEY, PCL .
IMMUNOLOGY LETTERS, 1987, 14 (04) :263-267
[2]   HIGH-RESOLUTION DUAL LASER FLOW CYTOMETRY [J].
DEAN, PN ;
PINKEL, D .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1978, 26 (08) :622-627
[3]   SINGLE LASER FLOW CYTOMETRIC DETECTION OF LYMPHOCYTES BINDING 3 ANTIBODIES LABELED WITH FLUORESCEIN, PHYCOERYTHRIN AND A NOVEL TANDEM FLUOROCHROME CONJUGATE [J].
FESTIN, R ;
BJORKLAND, A ;
TOTTERMAN, TH .
JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 126 (01) :69-78
[4]   FLUORESCENT TANDEM PHYCOBILIPROTEIN CONJUGATES - EMISSION WAVELENGTH SHIFTING BY ENERGY-TRANSFER [J].
GLAZER, AN ;
STRYER, L .
BIOPHYSICAL JOURNAL, 1983, 43 (03) :383-386
[5]  
LANIER LL, 1984, J IMMUNOL, V131, P2757
[6]  
MERKENSCHLAGER M, 1990, IN PRESS INT IMMUNOL
[7]  
OHASHI Y, 1989, J IMMUNOL, V143, P3548
[8]  
OVI VT, 1982, J CELL BIOL, V93, P981
[9]   3-COLOR IMMUNOFLUORESCENCE ANALYSIS OF MOUSE B-LYMPHOCYTE SUBPOPULATIONS [J].
PARKS, DR ;
HARDY, RR ;
HERZENBERG, LA .
CYTOMETRY, 1984, 5 (02) :159-168
[10]   HUMAN NAIVE AND MEMORY T-CELLS - REINTERPRETATION OF HELPER-INDUCER AND SUPPRESSOR-INDUCER SUBSETS [J].
SANDERS, ME ;
MAKGOBA, MW ;
SHAW, S .
IMMUNOLOGY TODAY, 1988, 9 (7-8) :195-199