A METHOD FOR THE RECOVERY OF NOISY MISSING DATA IN MOVEMENT ANALYSIS

被引:5
作者
STOKES, VP
机构
[1] Karolinska Institute, Physiology III, 11486 Stockholm
基金
英国医学研究理事会;
关键词
MISSING DATA; ORTHOGONAL POLYNOMIAL; KINEMATIC; MOVEMENT ANALYSIS;
D O I
10.1016/0169-2607(91)90082-5
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A new method is proposed for the accurate recovery of missing marker data obtained from movement tracking systems. The method has the form of a least-squares cubic polynomial approximation which is realized by the recursive expansion of orthogonal polynomials.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 9 条
[1]  
CONTE SD, 1987, ELEMENTARY NUMERICAL
[2]   ON THE ADAPTIVE INTERPOLATION OF DISCRETE-TIME SIGNALS [J].
DANTE, HM .
SIGNAL PROCESSING, 1989, 17 (04) :305-311
[3]  
de Boor C., 1978, PRACTICAL GUIDE SPLI
[4]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38
[5]  
Forsythe GE., 1977, COMPUTER METHODS MAT
[6]   ROTATIONAL AND TRANSLATIONAL MOVEMENT FEATURES OF THE PELVIS AND THORAX DURING ADULT HUMAN LOCOMOTION [J].
STOKES, VP ;
ANDERSSON, C ;
FORSSBERG, H .
JOURNAL OF BIOMECHANICS, 1989, 22 (01) :43-50
[8]  
Winter D. A., 1979, BIOMECHANICS HUMAN M
[9]   THE SIMULATION OF AERIAL MOVEMENT .1. THE DETERMINATION OF ORIENTATION ANGLES FROM FILM DATA [J].
YEADON, MR .