6R INSTRUMENTED SPATIAL LINKAGES FOR ANATOMICAL JOINT MOTION MEASUREMENT .1. DESIGN

被引:24
作者
KIRSTUKAS, SJ [1 ]
LEWIS, JL [1 ]
ERDMAN, AG [1 ]
机构
[1] UNIV MINNESOTA, DEPT ORTHOPAED SURG, MINNEAPOLIS, MN 55455 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1992年 / 114卷 / 01期
关键词
D O I
10.1115/1.2895455
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Six-revolute-joint instrumented spatial linkages (6R ISLs) have become often-used devices to measure the complete six-degree-of-freedom motion of anatomical joints. Accuracy of motion measurement depends on ISL design and calibration technique. In this paper, a design process is outlined that uses computer graphics and numerical methods as aids in developing 6R ISLs that (i) physically assemble within the desired range of motion of the joint; (ii) do not collide with either the experimental apparatus or the subject joint; (iii) avoid singular linkage configurations that can cause forces to be applied to the joint; and (iv) measure selected anatomical motions most accurately. It is found that a certain subgroup of 6R linkages are suitable for accurate measurement of specific motions, and can be the basis for new ISL designs. General guidelines are developed that can assist in the generation of unique linkage designs for different anatomical joints. The design process is demonstrated in the creation of an ISL to measure knee motion.
引用
收藏
页码:92 / 100
页数:9
相关论文
共 29 条
[1]   INVITRO LIGAMENT TENSION PATTERN IN THE FLEXED KNEE IN PASSIVE LOADING [J].
AHMED, AM ;
HYDER, A ;
BURKE, DL ;
CHAN, KH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (02) :217-230
[2]  
CHALKO TJ, 1987, EZPT MECANICS DEC, P423
[3]  
CHAO EYS, 1980, ASME, V102, P301
[4]  
Denavit J., 1955, J APPL MECH, V22, P215
[5]  
ERDMAN AG, 1984, ADV MECHANISM DESIGN, V1
[6]   A JOINT COORDINATE SYSTEM FOR THE CLINICAL DESCRIPTION OF 3-DIMENSIONAL MOTIONS - APPLICATION TO THE KNEE [J].
GROOD, ES ;
SUNTAY, WJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02) :136-144
[7]   LOAD SHARING AND GRAFT FORCES IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTIONS WITH THE LIGAMENT AUGMENTATION DEVICE [J].
HANLEY, P ;
LEW, WD ;
LEWIS, JL ;
HUNTER, RE ;
KIRSTUKAS, S ;
KOWALCZYK, C .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (03) :414-422
[8]   MEASUREMENT OF HIP-JOINT MOTION DURING WALKING - EVALUATION OF AN ELECTROGONIOMETRIC METHOD [J].
JOHNSTON, RC ;
SMIDT, GL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1969, A 51 (06) :1083-&
[9]   AN ELECTROGONIOMETRIC STUDY OF KNEE MOTION IN NORMAL GAIT [J].
KETTELKAMP, DB ;
JOHNSON, RJ ;
SMIDT, GL ;
CHAO, EYS ;
WALKER, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1970, A 52 (04) :775-+
[10]   MEASUREMENT OF TOTAL MOTION BETWEEN 2 BODY SEGMENTS .1. ANALYTICAL DEVELOPMENT [J].
KINZEL, GL ;
HILLBERRY, BM ;
HALL, AS .
JOURNAL OF BIOMECHANICS, 1972, 5 (01) :93-+