DETECTION AND ASSESSMENT OF INTRACRANIAL ANEURYSMS - VALUE OF CT ANGIOGRAPHY WITH SHADED-SURFACE DISPLAY

被引:61
作者
LIANG, EY
CHAN, M
HSIANG, JHK
WALKDEN, SB
POON, WS
LAM, WWM
METREWELI, C
机构
[1] CHINESE UNIV HONG KONG,PRINCE WALES HOSP,DEPT DIAGNOST RADIOL & ORGAN IMAGING,SHA TIN,HONG KONG
[2] CHINESE UNIV HONG KONG,PRINCE WALES HOSP,DEPT SURG,DIV NEUROSURG,SHA TIN,HONG KONG
关键词
D O I
10.2214/ajr.165.6.7484596
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the efficacy of circle of Willis CT angiography with shaded-surface display in the detection and assessment of suspected intracranial aneurysms. MATERIALS AND METHODS. Twenty-three patients who had clinical or radiologic suspicion of intracranial aneurysms were studied prospectively with CT angiography and conventional angiography. The images were obtained and interpreted in a double-blind fashion by different radiologists. Conventional angiography, which was the reference standard in this study, diagnosed 17 aneurysms in 15 patients. The usefulness of the two types of images for surgical planning was evaluated by two neurosurgeons, RESULTS. No aneurysms were detected with either technique in eight patients. Both techniques showed 15 aneurysms in 14 patients, The maximum dimensions were less than 3.0 mm in three cases, 3.0-5.0 mm in four cases, and greater than 5.0 mm in eight cases. With conventional angiography used as the reference standard, CT angiography has one false-positive and two false-negative findings, resulting in a sensitivity of 88% (15/17) and a specificity of 89% (8/9), For 12 of 15 aneurysms, CT angiography was rated equal or superior to conventional angiography in depicting all aspects (shape, orientation, neck, and parent vessel) of the aneurysms. CONCLUSION. We were able to detect aneurysms of the circle of Willis as small as 2 mm in size, Using conventional angiography as the reference standard, CT angiography has a sensitivity of 88% and a specificity of 89% for the detection of aneurysms in the circle of Willis, In almost all cases, CT angiography was equal or superior to conventional angiography in characterizing the aneurysms for surgical planning.
引用
收藏
页码:1497 / 1502
页数:6
相关论文
共 8 条
[1]  
AOKI S, 1992, AJNR, V13, P1127
[2]   SPIRAL CT ANGIOGRAPHY [J].
DILLON, EH ;
VANLEEUWEN, MS ;
FERNANDEZ, MA ;
MALI, WPTM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) :1273-1278
[3]  
DORCH NWC, 1995, NEUROSURGERY, V36, P230
[4]   3-DIMENSIONAL COMPUTERIZED-TOMOGRAPHY ANGIOGRAPHY IN THE DIAGNOSIS OF CEREBROVASCULAR-DISEASE [J].
HARBAUGH, RE ;
SCHLUSSELBERG, DS ;
JEFFERY, R ;
HAYDEN, S ;
CROMWELL, LD ;
PLUTA, D .
JOURNAL OF NEUROSURGERY, 1992, 76 (03) :408-414
[5]   CT ANGIOGRAPHY WITH SPIRAL CT AND MAXIMUM INTENSITY PROJECTION [J].
NAPEL, S ;
MARKS, MP ;
RUBIN, GD ;
DAKE, MD ;
MCDONNELL, CH ;
SONG, SM ;
ENZMANN, DR ;
JEFFREY, RB .
RADIOLOGY, 1992, 185 (02) :607-610
[6]   CT INFUSION SCANNING FOR THE DETECTION OF CEREBRAL ANEURYSMS [J].
NEWELL, DW ;
LEROUX, PD ;
DACEY, RG ;
STIMAC, GK ;
WINN, HR .
JOURNAL OF NEUROSURGERY, 1989, 71 (02) :175-179
[7]   EVALUATION OF CEREBRAL ANEURYSMS WITH HELICAL CT - CORRELATION WITH CONVENTIONAL ANGIOGRAPHY AND MR-ANGIOGRAPHY [J].
SCHWARTZ, RB ;
TICE, HM ;
HOOTEN, SM ;
HSU, LG ;
STIEG, PE .
RADIOLOGY, 1994, 192 (03) :717-722
[8]   CT ANGIOGRAPHY - EXPANDED CLINICAL-APPLICATIONS [J].
STEHLING, MK ;
LAWRENCE, JA ;
WEINTRAUB, JL ;
RAPTOPOULOS, V .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (04) :947-955