OXYGENATION-SENSITIVE CONTRAST IN MAGNETIC-RESONANCE IMAGE OF RODENT BRAIN AT HIGH MAGNETIC-FIELDS

被引:1514
作者
OGAWA, S
LEE, TM
NAYAK, AS
GLYNN, P
机构
[1] AT& T Bell Laboratories, Murray Hill, New Jersey
关键词
D O I
10.1002/mrm.1910140108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
At high magnetic fields (7 and 8.4 T), water proton magnetic resonance images of brains of live mice and rats under pentobarbital anesthetization have been measured by a gradient echo pulse sequence with a spatial resolution of 65 × 65‐μm pixel size and 700‐μm slice thickness. The contrast in these images depicts anatomical details of the brain by numerous dark lines of various sizes. These lines are absent in the image taken by the usual spin echo sequence. They represent the blood vessels in the image slice and appear when the deoxyhemoglobin content in the red cells increases. This contrast is most pronounced in an anoxy brain but not present in a brain with diamagnetic oxy or carbon monoxide hemoglobin. The local field induced by the magnetic susceptibility change in the blood due to the paramagnetic deoxyhemoglobin causes the intra voxel dephasing of the water signals of the blood and the surrounding tissue. This oxygena‐tion‐dependent contrast is appreciable in high field images with high spatial resolution. © 1990 Academic Press, Inc. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:68 / 78
页数:11
相关论文
共 16 条
[1]   APPLICATION OF SPIN-ECHO NUCLEAR MAGNETIC-RESONANCE TO WHOLE-CELL SYSTEMS - MEMBRANE-TRANSPORT [J].
BRINDLE, KM ;
BROWN, FF ;
CAMPBELL, ID ;
GRATHWOHL, C ;
KUCHEL, PW .
BIOCHEMICAL JOURNAL, 1979, 180 (01) :37-44
[2]   MAGNETIC-RESONANCE-IMAGING OF STATIONARY BLOOD - A REVIEW [J].
BROOKS, RA ;
DICHIRO, G .
MEDICAL PHYSICS, 1987, 14 (06) :903-913
[3]   THE EFFECT OF MAGNETIC-SUSCEPTIBILITY VARIATIONS IN NMR IMAGING AND NMR-SPECTROSCOPY INVIVO [J].
COX, IJ ;
BYDDER, GM ;
GADIAN, DG ;
YOUNG, IR ;
PROCTOR, E ;
WILLIAMS, SR ;
HART, I .
JOURNAL OF MAGNETIC RESONANCE, 1986, 70 (01) :163-168
[4]   VOLUME MAGNETIC SUSCEPTIBILITY MEASUREMENTS BY NMR [J].
DOUGLASS, DC ;
FRATIELLO, A .
JOURNAL OF CHEMICAL PHYSICS, 1963, 39 (11) :3161-+
[5]   RAPID SCAN MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
HART, HR .
MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (03) :238-245
[6]  
EIDELBERG D, 1988, MAGNET RESON MED, V6, P244
[7]   DIRECT FLASH MR IMAGING OF MAGNETIC-FIELD INHOMOGENEITIES BY GRADIENT COMPENSATION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (04) :474-480
[8]  
JACKSON JD, 1963, CLASSICAL ELECTRODYN, P110
[9]   NUCLEAR MAGNETIC RESONANCE CHEMICAL SHIFT DETERMINATIONS BY MEANS OF A CONCENTRIC CYLINDER SAMPLE CELL [J].
MORIN, MG ;
PAULETT, G ;
HOBBS, ME .
JOURNAL OF PHYSICAL CHEMISTRY, 1956, 60 (11) :1594-1596
[10]  
OGAWA S, IN PRESS MAGN RESON