ARSENIC SPECIATION BY MICELLAR LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC DETECTION

被引:65
作者
DING, H [1 ]
WANG, JS [1 ]
DORSEY, JG [1 ]
CARUSO, JA [1 ]
机构
[1] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
关键词
D O I
10.1016/0021-9673(94)01085-S
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Four environmentally and biologically important arsenic species, dimethylarsenic acid (DMA), monomethylarsonic acid (MMA), As(III) and As(V) are separated by micellar liquid chromatography. Linear dynamic ranges for the four species are three orders of magnitude and detection limits are in the picogram range with inductively coupled plasma mass spectrometric (ICP-MS) detection. This paper discusses in detail the development of the chromatographic conditions. The micellar mobile phase, which consisted of 0.05 M cetyltrimethylammonium bromide, 10% propanol and 0.02 M berate buffer, showed good compatibility with ICP-MS. This method allowed direct injection of urine samples onto the chromatographic system without extensive pretreatment and presented no interference from chlorine in the matrix. Detection limits are comparable with other LC-ICP-MS studies. An SRM urine sample was used to demonstrate the applicability of this technique to ''real-life'' situations. Results indicated that DMA, MMA and As(V) were present in the urine sample.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 20 条
[1]   USE OF AN AQUEOUS MICELLAR MOBILE PHASE FOR SEPARATION OF PHENOLS AND POLYNUCLEAR AROMATIC-HYDROCARBONS VIA HPLC [J].
ARMSTRONG, DW ;
HENRY, SJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1980, 3 (05) :657-662
[2]   PARTITIONING BEHAVIOR OF SOLUTES ELUTED WITH MICELLAR MOBILE PHASES IN LIQUID-CHROMATOGRAPHY [J].
ARMSTRONG, DW ;
NOME, F .
ANALYTICAL CHEMISTRY, 1981, 53 (11) :1662-1666
[3]   MICELLES IN SEPARATIONS - A PRACTICAL AND THEORETICAL REVIEW [J].
ARMSTRONG, DW .
SEPARATION AND PURIFICATION METHODS, 1985, 14 (02) :213-304
[4]   IDENTIFICATION AND QUANTITATION OF ARSENIC SPECIES IN A DOGFISH MUSCLE REFERENCE MATERIAL FOR TRACE-ELEMENTS [J].
BEAUCHEMIN, D ;
BEDNAS, ME ;
BERMAN, SS ;
MCLAREN, JW ;
SIU, KWM ;
STURGEON, RE .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2209-2212
[5]   DETERMINATION OF ARSENIC SPECIES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
SIU, KWM ;
MCLAREN, JW ;
BERMAN, SS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (03) :285-289
[6]   DETERMINATION OF ARSENIC SPECIES IN FISH BY DIRECTLY COUPLED HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY [J].
BRANCH, S ;
EBDON, L ;
ONEILL, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (01) :33-37
[7]   EFFICIENCY ENHANCEMENT IN MICELLAR LIQUID-CHROMATOGRAPHY [J].
DORSEY, JG ;
DEECHEGARAY, MT ;
LANDY, JS .
ANALYTICAL CHEMISTRY, 1983, 55 (06) :924-928
[8]  
DORSEY JG, 1987, ADV CHROMATOGR, V27, pCH5
[9]   CLARIFICATION OF THE LIMIT OF DETECTION IN CHROMATOGRAPHY [J].
FOLEY, JP ;
DORSEY, JG .
CHROMATOGRAPHIA, 1984, 18 (09) :503-511
[10]  
FOWLER BA, 1983, BIOL ENV EFFECT ARSE