INTRACRANIAL ANEURYSMS - DIAGNOSTIC-ACCURACY OF 3-DIMENSIONAL, FOURIER-TRANSFORM, TIME-OF-FLIGHT MR-ANGIOGRAPHY

被引:76
作者
KOROGI, Y
TAKAHASHI, M
MABUCHI, N
MIKI, H
FUJIWARA, S
HORIKAWA, Y
NAKAGAWA, T
OUCHI, T
WATABE, T
SHIGA, H
FURUSE, M
机构
[1] SOSEIKAI GEN HOSP,DEPT RADIOL,KYOTO,JAPAN
[2] EHIME UNIV,SCH MED,DEPT RADIOL,MATSUYAMA,EHIME,JAPAN
[3] KAMEDA MED CTR,DEPT RADIOL,CHIBA,JAPAN
[4] SAITAMA MED SCH,DEPT RADIOL,MOROYAMA,SAITAMA,JAPAN
[5] KEIO UNIV,SCH MED,DEPT RADIOL,TOKYO,JAPAN
[6] KOHNAN HOSP,DEPT NEUROSURG,SENDAI,MIYAGI,JAPAN
[7] KYOTO PREFECTURAL UNIV MED,DEPT NEUROSURG,KYOTO 602,JAPAN
[8] SHINSAPPORO NEUROSURG HOSP,DEPT NEUROSURG,SAPPORO,HOKKAIDO,JAPAN
[9] NAKATSUGAWA MUNICIPAL GEN HOSP,DEPT NEUROSURG,NAKATSUGAWA,OITA,JAPAN
关键词
ANEURYSM; INTRACRANIAL; BRAIN; MR; CEREBRAL BLOOD VESSELS; MR STUDIES; MAGNETIC RESONANCE; VASCULAR STUDIES;
D O I
10.1148/radiology.193.1.8090889
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the accuracy of three-dimensional, Fourier transform, time-of-flight magnetic resonance (MR) angiography in the identification of intracranial aneurysms. MATERIALS AND METHODS: MR angiograms of 126 patients (59 male and 67 female patients, aged 12-77 years) with various intracranial vascular lesions were evaluated. Seventy-eight aneurysms, including 60 less than 5 mm in diameter, in 61 patients were depicted at conventional angiography. Eight projection images, as well as one axial collapsed MR angiogram obtained with a maximum-intensity projection algorithm, were used for evaluation. RESULTS: Sensitivity for the five observers ranged from 58% to 68% (mean, 63%). Higher sensitivity was achieved for anterior communicating and middle cerebral artery aneurysms, while that for internal carotid artery aneurysms was poor. Sensitivities for small and medium aneurysms ranged from 50% to 60% (mean, 56%) and from 77% to 94% (mean, 86%), respectively. CONCLUSION: MR angiography can depict intracranial aneurysms 5 mm or larger with good accuracy but is less useful for the identification of smaller aneurysms.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 12 条
[2]   CEREBRAL MR-ANGIOGRAPHY WITH MULTIPLE OVERLAPPING THIN SLAB ACQUISITION .1. QUANTITATIVE-ANALYSIS OF VESSEL VISIBILITY [J].
BLATTER, DD ;
PARKER, DL ;
ROBISON, RO .
RADIOLOGY, 1991, 179 (03) :805-811
[4]   CEREBRAL ANGIOGRAPHIC RISK IN MILD CEREBROVASCULAR-DISEASE [J].
HANKEY, GJ ;
WARLOW, CP ;
SELLAR, RJ .
STROKE, 1990, 21 (02) :209-222
[5]  
HEINZ ER, 1993, AM J NEURORADIOL, V14, P974
[6]   CAROTID-ARTERY STENOSIS - CLINICAL EFFICACY OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY [J].
HEISERMAN, JE ;
DRAYER, BP ;
FRAM, EK ;
KELLER, PJ ;
BIRD, CR ;
HODAK, JA ;
FLOM, RA .
RADIOLOGY, 1992, 182 (03) :761-768
[7]   INTRACRANIAL ANEURYSMS AND VASCULAR MALFORMATIONS - COMPARISON OF TIME-OF-FLIGHT AND PHASE-CONTRAST MR ANGIOGRAPHY [J].
HUSTON, J ;
RUFENACHT, DA ;
EHMAN, RL ;
WIEBERS, DO .
RADIOLOGY, 1991, 181 (03) :721-730
[8]   AUTOPSY STUDY OF UNRUPTURED INCIDENTAL INTRACRANIAL ANEURYSMS [J].
INAGAWA, T ;
HIRANO, A .
SURGICAL NEUROLOGY, 1990, 34 (06) :361-365
[9]  
KOROGI Y, 1994, RADIOLOGY, V193
[10]   SIZE OF INTRACRANIAL SACCULAR ANEURYSMS - AN AUTOPSY STUDY [J].
MCCORMICK, WF ;
ACOSTARU.GJ .
JOURNAL OF NEUROSURGERY, 1970, 33 (04) :422-+